![IBM P 615 series Service Manual Download Page 218](http://html1.mh-extra.com/html/ibm/p-615-series/p-615-series_service-manual_4190796218.webp)
Table
6.
Service
Processor
Error
Codes.
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
450x
271B
System
backplane
with
1
processor
fault
Replace
the
CEC
backplane
Location:
U0.1-P1
450x
271C
System
backplane
with
2
processors
fault
Replace
the
CEC
backplane
Location:
U0.1-P1
450x
30D1
256
MB
DIMM
Go
to
“MAP
1240:
Memory
Problem
Resolution”
on
page
69.
450x
30D2
512
MB
DIMM
Go
to
“MAP
1240:
Memory
Problem
Resolution”
on
page
69.
450x
30D3
1
GB
DIMM
Go
to
“MAP
1240:
Memory
Problem
Resolution”
on
page
69.
450x
30D4
1
GB
DIMM
Go
to
“MAP
1240:
Memory
Problem
Resolution”
on
page
69.
450x
30D5
2
GB
DIMM
Go
to
“MAP
1240:
Memory
Problem
Resolution”
on
page
69.
460x
26F4
System
backplane
with
1
processor
Replace
the
system
backplane,
Location:
U0.1-P1
460x
26F5
System
backplane
with
2
processors
Replace
the
system
backplane,
Location:
U0.1-P1
460x
271B
System
backplane
with
1
processor
Replace
the
system
backplane,
Location:
U0.1-P1
460x
271C
System
backplane
with
2
processors
Replace
the
system
backplane,
Location:
U0.1-P1
460x
28D0
Service
processor
Replace
the
service
processor,
Location:
U0.1-P1-X1
4B23
26F5
Description:
2-way
processor
card
fault
Action:
This
error
code
indicates
that
the
processor
repeat
gard
function
has
deconfigured
a
processor.
Do
the
following:
1.
Go
to
the
processor
configuration/deconfiguration
menu,
located
under
the
system
information
menu
in
the
service
processor
menus.
Look
at
the
status
of
the
processors.
If
any
of
the
processors
have
a
status
of
manually
deconfigured
,
reconfigure
the
processor(s)
and
boot
the
system
to
the
SMS
menus.
Power
off
the
system
using
the
white
power
button
and
look
again
at
the
status
of
the
processors.
If
all
of
the
processors
are
still
configured
in
the
processor
configuration/deconfiguration
menu,
the
problem
has
been
resolved.
If
any
of
the
processors
have
a
status
of
deconfigured
by
the
system
,
either
before
or
after
the
boot
to
the
SMS
menus,
go
to
step
2.
2.
Replace
the
processor
card
(on
which
the
deconfigured
processor
resides)
specified
by
the
location
code.
198
Eserver
pSeries
615
Service
Guide
Summary of Contents for P 615 series
Page 1: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 2: ......
Page 3: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 12: ...x EserverpSeries 615 Service Guide...
Page 16: ...xiv EserverpSeries 615 Service Guide...
Page 18: ...xvi EserverpSeries 615 Service Guide...
Page 58: ...38 EserverpSeries 615 Service Guide...
Page 72: ...52 EserverpSeries 615 Service Guide...
Page 150: ...130 EserverpSeries 615 Service Guide...
Page 178: ...158 EserverpSeries 615 Service Guide...
Page 284: ...264 EserverpSeries 615 Service Guide...
Page 384: ...364 EserverpSeries 615 Service Guide...
Page 388: ...Model 6C3Parts 5 5 7 6 6 2 3 1 4 368 EserverpSeries 615 Service Guide...
Page 394: ...374 EserverpSeries 615 Service Guide...
Page 418: ...398 EserverpSeries 615 Service Guide...
Page 422: ...402 EserverpSeries 615 Service Guide...
Page 438: ...418 EserverpSeries 615 Service Guide...
Page 448: ...428 EserverpSeries 615 Service Guide...
Page 452: ...432 EserverpSeries 615 Service Guide...
Page 489: ......
Page 490: ...Printed in U S A October 2003 SA38 0630 02...
Page 491: ...Spine information pSeries 615 EserverpSeries 615 Service Guide SA38 0630 02...