Table
5.
Firmware
Error
Codes.
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
25A8
0100
NVRAM
data
validation
check
failed.
Turn
off,
then
turn
on
system
unit
and
retry
the
operation
before
replacing
any
system
component.
Refer
to
Action
under
error
code
25A80xxx.
25A8
0201
Unable
to
expand
target
partition
-
saving
configuration
variable.
Refer
to
Action
under
error
code
25A80xxx.
25A8
0202
Unable
to
expand
target
partition
-
writing
error
log
entry.
Refer
to
Action
under
error
code
25A80xxx.
25A8
0203
Unable
to
expand
target
partition
-
writing
VPD
data.
Refer
to
Action
under
error
code
25A80xxx.
25A8
0210
Setenv/$Setenv
parameter
error
-
name
contains
a
null
character.
Refer
to
Action
under
error
code
25A80xxx.
25A8
0215
NVRAM
RIO-USR-select
variable
not
found
1.
Check
for
platform
firmware
updates.
Apply
if
available.
2.
Call
service
support.
25A8
0211
Setenv/$Setenv
parameter
error
-
value
contains
a
null
character.
Refer
to
Action
under
error
code
25A80xxx.
25A8
0998
Description:
NVRAMRC
script
evaluation
error
-
command
line
execution
error
Action:
Execution
of
a
command
line
within
the
nvram
configuration
variable
“nvramrc”
(script)
resulted
in
a
“throw”
being
executed.
This
script
can
be
modified
by
the
system
firmware
SMS
utilities,
the
operating
system,
PCI
adapter
ROM
code
or
utility,
or
an
operator
(via
the
open
firmware
script
editing
command
nvedit
).
It
may
not
be
possible
to
resolve
the
problem
without
a
detailed
analysis
of
the
nvram
script,
the
current
system
configuration,
and
device
tree
contents.
1.
The
problem
can
be
caused
by
a
SCSI
adapter,
whose
SCSI
bus
ID
has
been
changed
from
the
default
setting,
no
longer
appearing
in
the
system.
This
can
be
caused
either
by
removing
a
SCSI
adapter,
or
a
problem
with
a
SCSI
adapter.
a.
Select
option
5,
Change
SCSI
Settings
,
on
the
SMS
main
menu.
Then
on
the
SCSI
utilities
menu,
select
option
2,
Change
SCSI
Id
.
1)
Verify
the
list
of
SCSI
controllers/adapters.
If
the
list
is
not
correct,
suspect
a
problem
with
the
adapter(s)
installed
but
not
listed.
2)
Select
one
of
the
adapters
listed
and
enter
the
SCSI
id
that
is
currently
displayed
for
that
adapter,
then
exit
from
this
menu.
This
causes
the
information
in
NVRAM
to
be
updated.
3)
Restart
the
system.
b.
If
the
problem
persists,
boot
the
operating
system
and
verify
the
SCSI
bus
IDs
of
any
installed/available
SCSI
controllers
(change
as
necessary),
and
restart
the
system.
2.
Contact
your
support
representative
for
further
assistance.
25A8
0999
NVRAMRC
script
evaluation
error
-
stack
unbalanced
on
completion
This
is
a
firmware
debug
environment
error.
There
is
no
user
action
or
FRU
replacement
for
this
error.
25A8
0A00
Unable
to
retrieve
NVRAM
LPAR
table
information
Refer
to
the
actions
column
for
error
code
25A8
0xxx.
Chapter
5.
Error
Code
to
FRU
Index
183
Summary of Contents for P 615 series
Page 1: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 2: ......
Page 3: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 12: ...x EserverpSeries 615 Service Guide...
Page 16: ...xiv EserverpSeries 615 Service Guide...
Page 18: ...xvi EserverpSeries 615 Service Guide...
Page 58: ...38 EserverpSeries 615 Service Guide...
Page 72: ...52 EserverpSeries 615 Service Guide...
Page 150: ...130 EserverpSeries 615 Service Guide...
Page 178: ...158 EserverpSeries 615 Service Guide...
Page 284: ...264 EserverpSeries 615 Service Guide...
Page 384: ...364 EserverpSeries 615 Service Guide...
Page 388: ...Model 6C3Parts 5 5 7 6 6 2 3 1 4 368 EserverpSeries 615 Service Guide...
Page 394: ...374 EserverpSeries 615 Service Guide...
Page 418: ...398 EserverpSeries 615 Service Guide...
Page 422: ...402 EserverpSeries 615 Service Guide...
Page 438: ...418 EserverpSeries 615 Service Guide...
Page 448: ...428 EserverpSeries 615 Service Guide...
Page 452: ...432 EserverpSeries 615 Service Guide...
Page 489: ......
Page 490: ...Printed in U S A October 2003 SA38 0630 02...
Page 491: ...Spine information pSeries 615 EserverpSeries 615 Service Guide SA38 0630 02...