![IBM P 615 series Service Manual Download Page 228](http://html1.mh-extra.com/html/ibm/p-615-series/p-615-series_service-manual_4190796228.webp)
Table
9.
Common
Firmware
Error
Codes
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
B1xx
4695
System
power
control
network
to
service
processor
interface
failure
1.
Check
for
system
firmware
updates.
2.
Service
processor
Location:
U0.1-P1-X1
B1xx
4696
System
firmware
interface
failure
1.
Check
for
system
firmware
updates.
2.
Call
service
support.
B1xx
4698
Firmware
problem
1.
Check
for
system
firmware
updates.
2.
Call
service
support.
B1xx
4699
Service
processor
firmware
error
or
informational
message.
See
B1xx
4699
in
“Error
Code
B1xx
4699”
on
page
209.
B1xx
469A
System
firmware
interface
1.
Check
for
system
firmware
updates.
2.
Call
service
support.
B1xx
469B
Firmware
to
I/O
interface
1.
Check
for
system
firmware
updates.
2.
CEC
backplane
Location:
U0.1-P1
B1xx
469C
Firmware
to
I/O
interface
1.
Check
for
system
firmware
updates.
2.
CEC
backplane
Location:
U0.1-P1
B1xx
469E
Service
processor
firmware
failure
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110
3.
CEC
backplane
Location:
U0.1-P1
B1xx
469F
Service
processor
failure
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110
3.
CEC
backplane
Location:
U0.1-P1
B1xx
8FF0
Informational
message
See
B1xx
8FF0
in
“Error
Code
B1xx
8FF0”
on
page
212.
B1FD
0013
A
firmware
update
has
failed
because
the
update
image
is
invalid.
The
update
was
stopped
before
any
changes
were
made
to
the
currently
installed
firmware.
Reset
the
service
processor
(by
activating
the
pinhole
reset
switch
or
by
disconnecting,
then
reconnecting
power).
Install
a
valid
firmware
update
image
for
the
specific
system
type
and
model.
B1FD
0015
Too
many
firmware
update
diskettes
inserted
(or
wrong
or
faulty
update
image)
1.
Ensure
the
firmware
update
image
is
correct
for
the
specific
system
type
and
model.
2.
Replace
the
update
diskettes
with
a
new
set
of
firmware
update
diskettes.
B1FD
0016
Diskette
read
error
1.
The
firmware
diskette
may
be
faulty.
Try
another
diskette.
2.
Replace
the
diskette
drive.
3.
Replace
the
CEC
backplane
Location:
U0.1-P1
208
Eserver
pSeries
615
Service
Guide
Summary of Contents for P 615 series
Page 1: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 2: ......
Page 3: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 12: ...x EserverpSeries 615 Service Guide...
Page 16: ...xiv EserverpSeries 615 Service Guide...
Page 18: ...xvi EserverpSeries 615 Service Guide...
Page 58: ...38 EserverpSeries 615 Service Guide...
Page 72: ...52 EserverpSeries 615 Service Guide...
Page 150: ...130 EserverpSeries 615 Service Guide...
Page 178: ...158 EserverpSeries 615 Service Guide...
Page 284: ...264 EserverpSeries 615 Service Guide...
Page 384: ...364 EserverpSeries 615 Service Guide...
Page 388: ...Model 6C3Parts 5 5 7 6 6 2 3 1 4 368 EserverpSeries 615 Service Guide...
Page 394: ...374 EserverpSeries 615 Service Guide...
Page 418: ...398 EserverpSeries 615 Service Guide...
Page 422: ...402 EserverpSeries 615 Service Guide...
Page 438: ...418 EserverpSeries 615 Service Guide...
Page 448: ...428 EserverpSeries 615 Service Guide...
Page 452: ...432 EserverpSeries 615 Service Guide...
Page 489: ......
Page 490: ...Printed in U S A October 2003 SA38 0630 02...
Page 491: ...Spine information pSeries 615 EserverpSeries 615 Service Guide SA38 0630 02...