Error
Code
Description
Action/
Possible
Failing
FRU
B1xx
4633
System
power
control
(SPCN)
network
failure
This
error
code
may
be
informational,
or
it
may
indicate
a
failure
in
the
SPCN
firmware
update.
Before
changing
any
parts,
examine
word
13
in
the
service
processor
error
log
entry,
or
bytes
68
and
69
in
the
AIX
error
log
entry.
For
detailed
instructions
on
finding
word
13
in
the
service
processor
error
log
entry,
or
bytes
68
and
69
in
the
AIX
error
log
entry,
refer
to
error
code
B1xx
4699
in
this
service
guide.
All
of
the
following
values
of
word
13
(or
bytes
68
and
69)
indicate
a
failure
of
an
SPCN
firmware
update:
A701
A702
A703
A704
A705
A706
A707
For
these
values
of
word
13,
do
the
following:
1.
Power
down
the
system.
2.
Collect
the
service
processor
error
log
data
for
the
B1xx
4633
error.
From
the
main
service
processor
menu,
enter
3
to
access
the
″
System
Information
menu.
Select
option
3,
″
Service
Processor
Error
Logs
″
.
3.
Collect
the
SPCN
trace
data.
From
the
main
service
processor
menu,
enter
3
to
access
the
″
System
Information
menu.
Select
option
9,
the
″
Power
Control
Network
Utilities
Menu
″
.
Then
select
option
4,
″
Collect
and
Display
the
SPCN
Trace
Data
″
.
4.
Power
on
the
system.
5.
Wait
10
minutes
after
the
system
has
reached
the
AIX
prompt.
Look
at
the
AIX
error
log
for
new
B1xx
4633
errors
with
the
word
13
values
(in
bytes
68
and
69
in
the
error
log
entry).
If
there
are
no
B1xx
4633
errors
with
matching
timestamps,
the
SPCN
down
load
was
successful.
If
the
download
failed
again
(there
is
another
B1xx
4633
error
in
the
AIX
error
log
with
the
correct
timestamp),
do
the
following:
a.
Power
down
the
system.
b.
Collect
the
service
processor
error
log
data
for
the
B1xx
4633
error
(see
step
2
above).
c.
Collect
the
SPCN
trace
data
(see
step
3
above).
d.
Contact
service
support.
For
all
other
values
of
word
13,
or
bytes
68
and
69,
do
the
following:
1.
Check
for
system
firmware
updates.
Apply
if
available.
2.
Call
service
support.
B1xx
4634
SPCN
loop
fault
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
B1xx
4643
I2C
card/flex
cable
detection
error
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
B1xx
4644
Processor
VPD
system
fault
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
B1xx
4645
I2C
(Non-processor)
VPD
System
Fault
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
B1xx
4646
General
VPD
fault
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
B1xx
4647
Write
TM
field
in
system
VPD
Replace
the
operator
panel,
location:
U0.1-L1.
Chapter
5.
Error
Code
to
FRU
Index
205
Summary of Contents for P 615 series
Page 1: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 2: ......
Page 3: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 12: ...x EserverpSeries 615 Service Guide...
Page 16: ...xiv EserverpSeries 615 Service Guide...
Page 18: ...xvi EserverpSeries 615 Service Guide...
Page 58: ...38 EserverpSeries 615 Service Guide...
Page 72: ...52 EserverpSeries 615 Service Guide...
Page 150: ...130 EserverpSeries 615 Service Guide...
Page 178: ...158 EserverpSeries 615 Service Guide...
Page 284: ...264 EserverpSeries 615 Service Guide...
Page 384: ...364 EserverpSeries 615 Service Guide...
Page 388: ...Model 6C3Parts 5 5 7 6 6 2 3 1 4 368 EserverpSeries 615 Service Guide...
Page 394: ...374 EserverpSeries 615 Service Guide...
Page 418: ...398 EserverpSeries 615 Service Guide...
Page 422: ...402 EserverpSeries 615 Service Guide...
Page 438: ...418 EserverpSeries 615 Service Guide...
Page 448: ...428 EserverpSeries 615 Service Guide...
Page 452: ...432 EserverpSeries 615 Service Guide...
Page 489: ......
Page 490: ...Printed in U S A October 2003 SA38 0630 02...
Page 491: ...Spine information pSeries 615 EserverpSeries 615 Service Guide SA38 0630 02...