Service
Request
Number
Description
and
Action
A03-03x
Description:
I/O
bridge/device
time-out,
access
or
other
error.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A03-04x
Description:
I/O
bridge/device
internal
error.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A03-05x
Description:
I/O
Error
on
non-PCI
bus.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A03-06x
Description:
Mezzanine
bus
address
parity
error.
A03-07x
Description:
System
bus
address
parity
error.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A03-08x
Description:
Mezzanine
bus
data
parity
error.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A03-09x
Description:
System
bus
data
parity
error.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A03-10x
Description:
Mezzanine
bus
time-out,
transfer
or
protocol
error.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A03-11x
Description:
System
bus
time-out
error.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A03-12x
Description:
Error
on
System
bus.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A03-13x
Description:
I/O
Expansion
bus
parity
error.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A03-14x
Description:
I/O
Expansion
bus
time-out
error.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A03-15x
Description:
I/O
Expansion
bus
connection
failure.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A03-16x
Description:
I/O
Expansion
unit
not
in
an
operating
state.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-00x
Description:
Error
log
analysis
indicates
an
environmental
and
power
warning,
but
the
failure
could
not
be
isolated.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-01x
Description:
Sensor
indicates
a
fan
has
failed.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-02x
Description:
System
shutdown
due
to
a
fan
failure.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-03x
Description:
Sensor
indicates
a
voltage
outside
normal
range.
Action:
Use
“MAP
1520:
Power”
on
page
98.
A05-04x
Description:
System
shutdown
due
to
voltage
outside
normal
range.
Action:
Use
“MAP
1520:
Power”
on
page
98.
Chapter
11.
SRNs
for
Linux
377
Summary of Contents for P 615 series
Page 1: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 2: ......
Page 3: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 12: ...x EserverpSeries 615 Service Guide...
Page 16: ...xiv EserverpSeries 615 Service Guide...
Page 18: ...xvi EserverpSeries 615 Service Guide...
Page 58: ...38 EserverpSeries 615 Service Guide...
Page 72: ...52 EserverpSeries 615 Service Guide...
Page 150: ...130 EserverpSeries 615 Service Guide...
Page 178: ...158 EserverpSeries 615 Service Guide...
Page 284: ...264 EserverpSeries 615 Service Guide...
Page 384: ...364 EserverpSeries 615 Service Guide...
Page 388: ...Model 6C3Parts 5 5 7 6 6 2 3 1 4 368 EserverpSeries 615 Service Guide...
Page 394: ...374 EserverpSeries 615 Service Guide...
Page 418: ...398 EserverpSeries 615 Service Guide...
Page 422: ...402 EserverpSeries 615 Service Guide...
Page 438: ...418 EserverpSeries 615 Service Guide...
Page 448: ...428 EserverpSeries 615 Service Guide...
Page 452: ...432 EserverpSeries 615 Service Guide...
Page 489: ......
Page 490: ...Printed in U S A October 2003 SA38 0630 02...
Page 491: ...Spine information pSeries 615 EserverpSeries 615 Service Guide SA38 0630 02...