8.
Enter
the
appropriate
password
if
you
are
prompted
to
do
so.
Is
the
Please
define
the
System
Console
screen
displayed?
NO
One
of
the
FRUs
remaining
in
the
system
unit
is
defective.
Exchange
the
FRUs
that
have
not
been
exchanged,
in
the
following
order:
1.
SCSI
cable
2.
Last
SCSI
device
connected
(for
example:
disk
drive,
tape
drive)
3.
CEC
backplane
(See
notes
on
page
53.)
Repeat
this
step
until
the
defective
FRU
is
identified
or
all
the
FRUs
have
been
exchanged.
If
the
symptom
did
not
change
and
all
the
FRUs
have
been
exchanged,
call
service
support
for
assistance.
If
the
symptom
has
changed,
check
for
loose
cards,
cables,
and
obvious
problems.
If
you
do
not
find
a
problem,
go
to
the
return
to
“Quick
Entry
MAP”
on
page
55
and
follow
the
instructions
for
the
new
symptom.
YES
Repeat
this
step,
adding
one
SCSI
device
at
a
time,
until
all
the
SCSI
devices
that
were
attached
to
the
integrated
SCSI
adapter,
except
the
disk
drive
backplanes,
are
connected
and
tested.
Go
to
“Step
1548-11.”
Step
1548-11
The
system
is
working
correctly
with
this
configuration.
One
of
the
disk
drive
backplanes
may
be
defective.
1.
Make
sure
the
diagnostic
CD-ROM
is
inserted
into
the
CD-ROM
drive.
2.
Turn
off
the
power
and
remove
the
power
cords.
3.
Connect
the
signal
and
power
connectors
to
one
of
the
disk
drive
backplanes.
4.
Plug
in
the
power
cords
and
wait
for
the
OK
prompt
to
display
on
the
operator
panel
display.
5.
Turn
on
the
power.
6.
If
the
Console
Selection
screen
is
displayed,
choose
the
system
console.
7.
After
the
word
keyboard
is
displayed,
press
the
number
5
key
on
either
the
directly
attached
keyboard
or
on
an
ASCII
terminal
keyboard.
8.
Enter
the
appropriate
password
if
you
are
prompted
to
do
so.
Is
the
Please
define
the
System
Console
screen
displayed?
NO
One
of
the
FRUs
remaining
in
the
system
unit
is
defective.
Exchange
the
FRUs
that
have
not
been
exchanged,
in
the
following
order:
1.
SCSI
cable
2.
Disk
drive
backplane
Repeat
this
step
until
the
defective
FRU
is
identified
or
all
the
FRUs
have
been
exchanged.
If
the
symptom
did
not
change
and
all
the
FRUs
have
been
exchanged,
call
service
support
for
assistance.
If
the
symptom
has
changed,
check
for
loose
cards,
cables,
and
obvious
problems.
If
you
do
not
find
a
problem,
go
to
the
“Quick
Entry
MAP”
on
page
55
and
follow
the
instructions
for
the
new
symptom.
YES
If
both
disk
drive
backplanes
have
been
reconnected,
go
to
“Step
1548-12”
on
page
119.
Otherwise,
repeat
“Step
1548-11”
for
the
other
disk
drive
backplane.
118
Eserver
pSeries
615
Service
Guide
Summary of Contents for P 615 series
Page 1: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 2: ......
Page 3: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 12: ...x EserverpSeries 615 Service Guide...
Page 16: ...xiv EserverpSeries 615 Service Guide...
Page 18: ...xvi EserverpSeries 615 Service Guide...
Page 58: ...38 EserverpSeries 615 Service Guide...
Page 72: ...52 EserverpSeries 615 Service Guide...
Page 150: ...130 EserverpSeries 615 Service Guide...
Page 178: ...158 EserverpSeries 615 Service Guide...
Page 284: ...264 EserverpSeries 615 Service Guide...
Page 384: ...364 EserverpSeries 615 Service Guide...
Page 388: ...Model 6C3Parts 5 5 7 6 6 2 3 1 4 368 EserverpSeries 615 Service Guide...
Page 394: ...374 EserverpSeries 615 Service Guide...
Page 418: ...398 EserverpSeries 615 Service Guide...
Page 422: ...402 EserverpSeries 615 Service Guide...
Page 438: ...418 EserverpSeries 615 Service Guide...
Page 448: ...428 EserverpSeries 615 Service Guide...
Page 452: ...432 EserverpSeries 615 Service Guide...
Page 489: ......
Page 490: ...Printed in U S A October 2003 SA38 0630 02...
Page 491: ...Spine information pSeries 615 EserverpSeries 615 Service Guide SA38 0630 02...