The
service
processor
menus
are
password-protected.
Before
you
can
access
them,
you
need
either
the
general
user-password
or
privileged-user
password.
Service
processor
menus
are
available
on
ASCII
terminals
attached
to
the
serial
ports
on
the
system,
and
on
terminal
emulators.
On
HMC-managed
systems,
service
processor
menus
are
also
available
on
the
HMC
graphical
user
interface.
Bring-Up
Phase
This
phase
is
entered
upon
power-on,
and
exited
upon
loading
of
the
operating
system.
The
bring-up
phase
components
are
as
follows:
v
Retry
Request
Check
The
service
processor
checks
to
see
if
the
previous
boot
attempt
failed.
If
the
specified
number
of
failures
are
detected,
the
service
processor
displays
an
error
code
and
places
an
outgoing
call
to
notify
an
external
party
if
the
user
has
enabled
this
option.
v
Dial
Out
The
service
processor
can
dial
a
preprogrammed
telephone
number
in
the
event
of
an
IPL
failure.
The
service
processor
issues
an
error
report
with
the
last
reported
IPL
status
indicated
and
any
other
available
error
information.
v
Update
Operator
Panel
The
service
processor
displays
operator
panel
data
on
the
HMC
virtual
terminal
window
if
a
remote
connection
is
active.
v
Environmental
Monitoring
The
service
processor
provides
expanded
error
recording
and
reporting.
v
System
Firmware
Surveillance
(Heartbeat
Monitoring)
The
service
processor
monitors
and
times
the
interval
between
system
firmware
heartbeats.
v
Responding
to
System
Processor
Commands
The
service
processor
responds
to
any
command
issued
by
the
system
processor.
Runtime
Phase
This
phase
includes
the
tasks
that
the
service
processor
performs
during
steady-state
execution
of
the
operating
system.
v
Environmental
Monitoring
The
service
processor
monitors
voltages,
temperatures,
and
fan
speeds
(on
some
servers).
v
Responding
to
System
Processor
Commands
The
service
processor
responds
to
any
command
issued
by
the
system
processor.
v
Run-Time
Surveillance
If
the
device
driver
is
installed
and
surveillance
enabled,
the
service
processor
monitors
the
system
heartbeat.
If
the
heartbeat
times
out,
the
service
processor
places
an
outgoing
call.
This
is
different
from
the
bring-up
phase
scenario,
where
the
specified
number
of
reboot
attempts
are
made
before
placing
an
outgoing
call.
v
HMC
surveillance
On
an
HMC-managed
system,
the
service
processor
monitors
the
communication
link
between
the
managed
system
and
the
HMC.
If
the
service
processor
detects
that
this
communication
link
has
been
broken,
it
will
post
an
error
to
the
operating
system
running
on
the
managed
system.
Chapter
7.
Using
the
Service
Processor
263
Summary of Contents for P 615 series
Page 1: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 2: ......
Page 3: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 12: ...x EserverpSeries 615 Service Guide...
Page 16: ...xiv EserverpSeries 615 Service Guide...
Page 18: ...xvi EserverpSeries 615 Service Guide...
Page 58: ...38 EserverpSeries 615 Service Guide...
Page 72: ...52 EserverpSeries 615 Service Guide...
Page 150: ...130 EserverpSeries 615 Service Guide...
Page 178: ...158 EserverpSeries 615 Service Guide...
Page 284: ...264 EserverpSeries 615 Service Guide...
Page 384: ...364 EserverpSeries 615 Service Guide...
Page 388: ...Model 6C3Parts 5 5 7 6 6 2 3 1 4 368 EserverpSeries 615 Service Guide...
Page 394: ...374 EserverpSeries 615 Service Guide...
Page 418: ...398 EserverpSeries 615 Service Guide...
Page 422: ...402 EserverpSeries 615 Service Guide...
Page 438: ...418 EserverpSeries 615 Service Guide...
Page 448: ...428 EserverpSeries 615 Service Guide...
Page 452: ...432 EserverpSeries 615 Service Guide...
Page 489: ......
Page 490: ...Printed in U S A October 2003 SA38 0630 02...
Page 491: ...Spine information pSeries 615 EserverpSeries 615 Service Guide SA38 0630 02...