Table
5.
Firmware
Error
Codes.
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
20EE
0020
The
environment
variable
″
boot-device
″
exceeds
the
allowed
character
limit.
If
this
error
occurs
during
the
installation
of
AIX
by
a
″
NIM
push
″
,
the
set_bootlist
attribute
may
not
have
been
set
correctly
on
the
NIM
master.
For
more
information,
see
the
AIX
5.2
Installation
Guide
and
Reference
,
order
number
SC23-4389.
If
this
error
occurs
at
any
other
time:
1.
Check
for
platform
firmware
updates.
Apply
if
available.
2.
Call
service
support.
20EE
0021
The
environment
variable
″
boot-device
″
contained
more
than
five
entries
If
this
error
occurs
during
the
installation
of
AIX
by
a
″
NIM
push
″
,
the
set_bootlist
attribute
may
not
have
been
set
correctly
on
the
NIM
master.
For
more
information,
see
the
AIX
5.2
Installation
Guide
and
Reference
,
order
number
SC23-4389.
If
this
error
occurs
at
any
other
time:
1.
Check
for
platform
firmware
updates.
Apply
if
available.
2.
Call
service
support.
20EE
0022
The
environment
variable
″
boot-device
″
contained
an
entry
that
exceeded
255
characters
in
length
If
this
error
occurs
during
the
installation
of
AIX
by
a
″
NIM
push
″
,
the
set_bootlist
attribute
may
not
have
been
set
correctly
on
the
NIM
master.
For
more
information,
see
the
AIX
5.2
Installation
Guide
and
Reference
,
order
number
SC23-4389.
If
this
error
occurs
at
any
other
time:
1.
Check
for
platform
firmware
updates.
Apply
if
available.
2.
Call
service
support.
20EE
0100
Fcode
resident
on
an
I/O
adapter
is
not
supported
on
this
system
Informational
message.
The
adapter’s
Fcode
driver
is
not
supported
on
this
system.
Additional
information
may
be
available
from
service
support.
This
error
code
only
affects
boot-time
operation,
not
the
adapter’s
functionality
under
the
operating
system.
20FC
0020
Failed
to
retrieve
power,
packaging,
and/or
cooling
VPD
via
SPCN
for
the
corresponding
subsystem.
Service
processor
mailbox
failed
to
get
VPD.
1.
Check
the
RIO
cabling.
2.
Check
for
system
firmware
updates.
3.
Replace
the
part
specified
by
the
location
code.
20FC
0021
Failed
to
retrieve
power,
packaging,
and/or
cooling
VPD
via
SPCN
for
the
corresponding
subsystem.
Service
processor
mailbox
failed
to
get
power,
packaging,
and
cooling
device
VPD.
1.
Check
the
RIO
cabling.
2.
Check
for
system
firmware
updates.
3.
Replace
the
part
specified
by
the
location
code.
178
Eserver
pSeries
615
Service
Guide
Summary of Contents for P 615 series
Page 1: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 2: ......
Page 3: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 12: ...x EserverpSeries 615 Service Guide...
Page 16: ...xiv EserverpSeries 615 Service Guide...
Page 18: ...xvi EserverpSeries 615 Service Guide...
Page 58: ...38 EserverpSeries 615 Service Guide...
Page 72: ...52 EserverpSeries 615 Service Guide...
Page 150: ...130 EserverpSeries 615 Service Guide...
Page 178: ...158 EserverpSeries 615 Service Guide...
Page 284: ...264 EserverpSeries 615 Service Guide...
Page 384: ...364 EserverpSeries 615 Service Guide...
Page 388: ...Model 6C3Parts 5 5 7 6 6 2 3 1 4 368 EserverpSeries 615 Service Guide...
Page 394: ...374 EserverpSeries 615 Service Guide...
Page 418: ...398 EserverpSeries 615 Service Guide...
Page 422: ...402 EserverpSeries 615 Service Guide...
Page 438: ...418 EserverpSeries 615 Service Guide...
Page 448: ...428 EserverpSeries 615 Service Guide...
Page 452: ...432 EserverpSeries 615 Service Guide...
Page 489: ......
Page 490: ...Printed in U S A October 2003 SA38 0630 02...
Page 491: ...Spine information pSeries 615 EserverpSeries 615 Service Guide SA38 0630 02...