The
following
figure
shows
the
rear
view
of
the
I/O
subsystem.
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
11
10
12
1
PCI
adapter
slot
1
7
RIO
bus
adapter
card
Upper
connector
0
Lower
connector
1
2
PCI-X
adapter
slot
2
8
SPCN
connector
card
3
PCI-X
adapter
slot
3
9
Lower
SPCN
connector
J16
4
PCI-X
adapter
slot
4
10
Upper
SPCN
connector
J15
5
PCI-X
adapter
slot
5
11
Rack
beacon
connector
6
PCI-X
adapter
slot
6
12
Power
cord
channel
D10
Operator
Indicators
LEDs
are
used
on
the
Model
D10
as
operator
indicators.
LEDs
can
be
found
on
or
near
the
following
FRUs:
v
LED
indicators
visible
on
each
PCI
adapter
cassette
v
LED
indicators
on
the
I/O
subsystem
backplane
v
Attention/Identify
LEDs
for
power
supplies
and
fans
For
more
information
on
LEDs
and
their
definitions,
see
Chapter
5,
“Fault
and
Attention
LEDs,”
on
page
173.
D10
PCI-X
Slots
The
Model
D10
has
five
PCI-X
slots
and
one
PCI
slot.
Adapters
are
installed
and
removed
using
a
PCI
adapter
cassette,
which
allows
adapters
to
be
installed
without
turning
off
the
power
or
opening
the
I/O
subsystem
covers.
PCI
adapters
are
installed
using
an
adapter
cassette,
each
adapter
cassette
shows
two
LEDs
for
each
adapter.
There
is
a
green
power
indicator
LED
(upper)
and
an
amber
fault/identify
LED
(lower).
The
slots
are
numbered
on
the
rear
of
the
chassis
from
left
to
right
1
through
6.
Slot
1
is
a
5V
PCI
slot.
Slots
2
through
6
are
3.3V
PCI-X.
I/O
Subsystem
PCI-X
Slot
LED
Definitions
The
green
and
amber
LEDs
(viewed
on
the
rear
of
the
PCI
adapter
cassette
when
installed)
are
used
to
indicate
the
state
of
the
PCI
slot
during
removal
and
replacement
of
an
adapter.
The
following
table
describes
the
LED
states
and
their
definitions.
2
Eserver
pSeries
7311
Model
D10
and
Model
D20
Service
Guide
Summary of Contents for eserver pSeries 7311 D10
Page 1: ...pSeries 7311 Model D10 and Model D20 Service Guide SA38 0627 01 ERserver...
Page 2: ......
Page 3: ...pSeries 7311 Model D10 and Model D20 Service Guide SA38 0627 01 ERserver...
Page 8: ...vi Eserver pSeries 7311 Model D10 and Model D20 Service Guide...
Page 12: ...x Eserver pSeries 7311 Model D10 and Model D20 Service Guide...
Page 14: ...xii Eserver pSeries 7311 Model D10 and Model D20 Service Guide...
Page 25: ...1 Processor Subsystem 2 I O Subsystem Chapter 1 Reference Information 9...
Page 89: ...Chapter 3 Removal and Replacement Procedures 73...
Page 99: ...2 1 1 Top of Cassette 2 Handle Chapter 3 Removal and Replacement Procedures 83...
Page 179: ...D10 I O Subsystem Parts continued 1 2 3 4 5 6 7 Chapter 4 Parts Information 163...
Page 207: ......