16
BRAKE SYSTEM
>------400379-10
G02092-10
G02093-10
-
Open shut-off valve
8.
•
Info
I
Follow the operating instructions of the bleeding device.
117
-
Ensure that the filling pressure is set on pressure gauge t). Correct the filling
pressure on pressure regulator
0
if necessary.
Guideline
I
Filling pressure
I
2 ... 2.5 bar (29 ... 36 psi)
-
Pull off protection cap
0
of the brake caliper bleeder screw. Connect the
bleeder bottle hose.
I
Bleeding device (00029013100) (
!lll
p. 288)
-
Open bleeder screw Q) by approx. one half turn.
•
Info
I
Drain until fresh brake fluid emerges in the bleeder bottle hose without
bubbles.
-
Tighten the bleeder screw.
-
Close shut-off valve
8.
-
Open the bleeder screw again until brake fluid stops emerging.
•
Info
I
Overfilling of the brake fluid reservoir is prevented.
-
Tighten the bleeder screw. Remove the bleeder bottle hose. Mount the pro
tection cap.
-
Disconnect the bleeding device. Remove the bleeder cover.
-
Correct the brake fluid to level Q).
Guideline
I
Level Q)
I
Brake fluid DOT 4 (
�
p. 284)
I
5 mm (0.2 in)
-
Position the cover with the membrane. Mount and tighten the screws.
•
Info
I
Clean up overflowed or spilled brake fluid immediately with water.
-
Check the hand brake lever for a firm pressure point.
(FE 350S US)
-
Move the brake fluid reservoir mounted on the handlebar to a horizontal posi-
tion.
-
Cover painted parts.
-
Remove screws
O.
-
Remove cover @ with the membrane.
-
Draw the old brake fluid out of the brake fluid reservoir using a syringe and fill
with fresh brake fluid.
Bleed syringe (50329050000) (
a
p. 289)
Brake fluid DOT 4 (
�
p. 284)
-
Mount bleeder cover
8.
I
Bleeder cover (00029013005) (
�
p. 288)
-
Connect the bleeding device.
I
Bleeding device (00029013100) (
a
p. 288)
Summary of Contents for FE 350 2015