04/SHOCK ABSORBER, SWINGARM
49
200269-10
–
As soon as the pressure gauge has attained the specified value, turn the
Damper
control lever to
Vacuum
.
Guideline
3 bar
The pressure gauge drops to the specified value.
0 bar
–
As soon as the pressure gauge has attained the specified value hat, turn off the
On/Off
switch.
Guideline
0 bar
The vacuum pump has been switched off.
200783-10
–
Slide O-ring
to the end of the special tool by the specified value (distance
minus specification).
Guideline
10 mm
Depth micrometer (T107S) (
–
Push the floating piston into the reservoir using the special tool up to the reduced
dimension.
Info
The floating piston must be set precisely to this position with the piston rod
fully extended, as otherwise damage could occur when the shock absorber is
compressed.
–
Remove the special tool.
200784-10
–
Remove adapter
from connection
of the vacuum pump.
Info
Hold the shock absorber in such a way that the filling port is positioned at
the highest point.
–
Remove the adapter.
–
Mount and tighten screw
.
Guideline
Filling port screw
M10x1
14 Nm
(10.3 lbf ft)
7.26
Filling the shock absorber with nitrogen
200814-10
–
Screw in the screw
approx. two turns, but do not tighten.
Info
The piston rod is completely extended.
200815-10
–
Keep the special tool in place in the bench vise.
Nitrogen filling tool (T170S1) (
–
Connect the special tool to the pressure regulator of the filling cylinder.
Filling gas - nitrogen
–
Adjust the pressure regulator.
Guideline
Gas pressure
10 bar (145 psi)