FAULT CODE
165
400588-10
400607-11
Heating lambda sensor - check the power supply
–
Measure the voltage between the specified points.
Connector
CU
Pin
3
–
measuring point
Ground(
−
)
Info
For the measurement, the measurement points must be loaded with a 12V/21W bulb.
The value should not vary more than 1V from the battery voltage
"VBAT"
.
» If the measured value does not correspond to the specified value:
–
Check connector
CU
pin
3
.
–
Check the cable from connector
CU
pin
3
to the next node in the cable harness for an open circuit.
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Heating lambda sensor - value is not plausible (
Heating lambda sensor - value is not plausible
Condition
Th e diagnostic tool is disconnected.
Lambda sensor is disconnected.
400596-10
Heating lambda sensor - check the resistance
–
Measure the resistance between the specified points.
Connector
DY
Pin
3
–
Connector
DY
Pin
4
Heating lambda sensor
Resistance at: 20 °C (68 °F)
6.9… 8.5
Ω
» If the measured value does not correspond to the specified value:
–
Check connector
DY
pin
3
and connector
DY
pin
4
.
–
Check the cable of the lambda sensor to connector
DY
pin
3
and connector
DY
pin
4
.
–
Change the lambda sensor.
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Heating lambda sensor - control line is open (
Heating lambda sensor - control line is open
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
Lambda sensor is disconnected.
Summary of Contents for FE 450 AUS