FAULT CODE
212
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Fuel pump - power supply is faulty (
Fuel pump - power supply is faulty
Condition
The diagnostic tool is connected and active.
The breakout box is connected to the EFI control unit and wiring harness.
600849-01
400607-11
Fuel pump - check the power supply
–
Measure the voltage between the specified points.
Break Out Box
DT
Pin
14
–
measuring point
Ground(
−
)
Info
For the measurement, the measurement points must be loaded with a 12V/21W bulb.
The value should not vary more than 1V from the battery voltage
"VBAT"
.
» If the measured value does not correspond to the specified value:
–
Check the cable from the connector of fuse pin
2
to connector
DT
pin
14
for an open circuit.
» If the measured value corresponds to the specified value:
–
Contact customer service.