30/ENGINE - WORK ON THE INDIVIDUAL PARTS
122
19.22
Checking the oil pumps for wear
300358-10
–
Use feeler gauge
to measure the play between the external rotor and the engine
case.
Oil pump
External rotor/engine case clear-
ance
≤
0.20 mm (
≤
0.0079 in)
» If the measured value does not comply with the specification:
–
Replace the oil pump or, as the case may be, engine case.
300359-10
–
Use feeler gauge
to measure the play between the external rotor and the internal
rotor.
Oil pump
External rotor/internal rotor clear-
ance
≤
0.20 mm (
≤
0.0079 in)
» If the measured value does not comply with the specification:
–
Replace the oil pump.
19.23
Disassembling the autodecompressor
300450-10
–
Take lock ring
from the autodecompression shaft and dispose of it.
300451-10
–
Pull autodecompression shaft
out of the camshaft.
300452-10
–
Release and remove autodecompression spring
.
Info
Autodecompression weight
cannot be taken off.