![HUSABERG FE 450 AUS Repair Manual Download Page 209](http://html1.mh-extra.com/html/husaberg/fe-450-aus/fe-450-aus_repair-manual_2187561209.webp)
FAULT CODE
207
600849-01
400607-11
Ignition coil - check the control line for an open circuit
–
Measure the voltage between the specified points.
Break Out Box
DT
Pin
18
–
measuring point
Ground(
−
)
Info
For the measurement, the measurement points must be loaded with a 12V/21W bulb.
The value should not vary more than 1V from the battery voltage
"VBAT"
.
» If the measured value does not correspond to the specified value:
–
Check connector
DT
pin
18
and connector pin
1
at the ignition coil.
–
Check the cable from connector
DT
pin
18
to connector pin
1
at the ignition coil for an open circuit.
» If the measured value corresponds to the specified value:
–
Contact customer service.