![HUSABERG FE 450 AUS Repair Manual Download Page 50](http://html1.mh-extra.com/html/husaberg/fe-450-aus/fe-450-aus_repair-manual_2187561050.webp)
04/SHOCK ABSORBER, SWINGARM
48
200267-10
–
As soon as the vacuum gauge has attained the specified value, turn the
Oil reser-
voir
control lever to
Equalize pressure
.
Guideline
4 mbar
The pressure gauge rises to the specified value.
0 bar
200268-10
–
As soon as the pressure gauge has attained the specified value, turn the
Damper
control lever to
Pressure
.
Guideline
0 bar
Oil is pumped into the shock absorber.
The pressure gauge rises to the specified value.
3 bar
200269-10
–
As soon as the pressure gauge has attained the specified value, turn the
Damper
control lever to
Vacuum
.
Guideline
3 bar
The pressure gauge drops to the specified value.
0 bar
200270-10
–
As soon as the pressure gauge has attained the specified value, turn the
Oil reser-
voir
control lever to
Vacuum
.
Guideline
0 bar
The vacuum gauge drops to the specified value.
8 mbar
200267-10
–
As soon as the vacuum gauge has attained the specified value, turn the
Oil reser-
voir
control lever to
Equalize Pressure
.
Guideline
8 mbar
The pressure gauge drops to the specified value.
0 bar
200268-10
–
As soon as the pressure gauge has attained the specified value, turn the
Damper
control lever to
Pressure
.
Guideline
0 bar
Oil is pumped into the shock absorber.
The pressure gauge rises to the specified value.
3 bar