FAULT CODE
187
600849-01
400597-10
Throttle position sensor - check the signal line for an open circuit
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
5
–
Connector
EX
Pin
1
Resistance
≤
0.6
Ω
» If the measured value does not correspond to the specified value:
–
Check connector
DT
pin
5
and connector
EX
pin
1
.
–
Check the cable from connector
DT
pin
5
to connector
EX
pin
1
for an open circuit.
» If the measured value corresponds to the specified value:
–
Contact customer service.