01/FORK, TRIPLE CLAMP
19
5.15
Disassembling the compression damping fitting
Info
The steps are identical for both fork legs.
–
Disassemble the fork legs. (
200702-10
–
Clamp the compression damping fitting in a bench vise using soft jaws.
–
Remove nut
.
–
Remove the spring.
–
Remove washer
.
200703-10
–
Remove piston
.
–
Remove shim stack
.
200704-10
–
Remove O-ring
and seal ring
from the compression damping fitting.
–
Extract the compression damping fitting.
5.16
Checking the fork legs
Condition
The fork legs are disassembled.
200728-10
–
Check the inner tube and axle clamp for damage.
» If there is damage:
–
Replace the inner tube.
200684-10
–
Measure the outside diameter at several points of the inner tube.
Outside diameter of the inner tube
47.975… 48.005 mm (1.88878…
1.88996 in)
» If the measured value is smaller than the specified value:
–
Replace the inner tube.