![HUSABERG FE 450 AUS Repair Manual Download Page 201](http://html1.mh-extra.com/html/husaberg/fe-450-aus/fe-450-aus_repair-manual_2187561201.webp)
FAULT CODE
199
Flash code FI warning
lamp (MIL)
02
FI
warning lamp (
MIL
) flashes 2x short
Display on diagnostic tool
P0335
"Circuit ignition pulse generator"
"Malfunction in the circuit"
Error level condition
The manifold absolute pressure sensor is generating a standard signal (the engine is running),
whereas the ignition pulse generator is not generating any signal.
The engine will be switched off:
≥
1 s
Function check
Ignition pulse generator - checking the signal (
Possible cause
Ignition pulse generator - value not plausible (
Ignition pulse generator - signal lines are open (
Ignition pulse generator - signal lines have a short circuit to each other (
Ignition pulse generator - signal lines have a short circuit to ground (terminal 31) (
Ignition pulse generator - signal lines have a short circuit to sensor ground (
Ignition pulse generator - signal lines have a short circuit to plus (terminal 30) (
Ignition pulse generator - signal lines have a short circuit to ignition plus (terminal 15)
Ignition pulse generator - signal line has a short circuit to the sensor power supply (
Ignition pulse generator - checking the signal
Condition
The diagnostic tool is connected and active.
–
Select the model type.
–
Select
"ECU Diagnostic"
.
–
Highlight the
"Engine electronics EXC"
control unit.
–
Press
"Continue"
.
–
Select
"Measurement values"
.
–
Highlight
"Starter"
.
–
Press
"Continue"
.
–
Highlight the measured value
"Engine speed (NE)"
and deselect the other parameters with
"Select measured value"
.
–
Perform the starting procedure.
"Engine speed (NE)"
Starter speed
» If the specification is attained:
–
Delete the fault code.
–
Make a test ride.
–
Read out the fault code.
» If the specification is not attained:
–
Check the next possible cause:
Ignition pulse generator - value not plausible (
Ignition pulse generator - value not plausible
Condition
Ignition pulse generator is disconnected.
400585-10
Ignition pulse generator - check the resistance
–
Measure the resistance between the specified points.
Connector
AT
Pin
1
–
Connector
AT
Pin
2
Pulse generator
Resistance at: 20 °C (68 °F)
80… 120
Ω
» If the measured value does not correspond to the specified value:
–
Change the ignition pulse generator.
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Ignition pulse generator - signal lines are open (
Summary of Contents for FE 450 AUS
Page 2: ......
Page 237: ...235...
Page 243: ...WIRING DIAGRAM 241...
Page 247: ...WIRING DIAGRAM 245...
Page 253: ...WIRING DIAGRAM 251...
Page 261: ...WIRING DIAGRAM 259...