FAULT CODE
214
600849-01
400607-11
Rollover sensor - check the signal line for a short circuit to ground (terminal 31)
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
2
–
measuring point
Ground(
−
)
Resistance
∞ Ω
» If the measured value does not correspond to the specified value:
–
Check the cable from connector
DT
pin
2
to connector
AP
pin
5
for a short circuit to ground (terminal 31).
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Rollover sensor - signal line has a short circuit to sensor ground (
Rollover sensor - signal line has a short circuit to sensor ground
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
The rollover sensor is disconnected.
600849-01
Rollover sensor - check the signal line for a short circuit to sensor ground
–
Measure the resistance between the specified points.
Break Out Box
DT
Pin
2
–
Break Out Box
DT
Pin
24
Resistance
∞ Ω
» If the measured value does not correspond to the specified value:
–
Check the cable from connector
DT
pin
2
to connector
AP
pin
5
for a short cir-
cuit to sensor ground.
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Rollover sensor - power supply is open (
Rollover sensor - power supply is open
Condition
The diagnostic tool is connected and active.
The EFI control unit is connected.
The rollover sensor is disconnected.
400583-10
400607-11
Rollover sensor - check the power supply
–
Measure the voltage between the specified points.
Connector
AP
Pin
6
–
measuring point
Ground(
−
)
Voltage
4.9… 5.1 V
Summary of Contents for FE 450 AUS
Page 2: ......
Page 237: ...235...
Page 243: ...WIRING DIAGRAM 241...
Page 247: ...WIRING DIAGRAM 245...
Page 253: ...WIRING DIAGRAM 251...
Page 261: ...WIRING DIAGRAM 259...