![Huawei NetCol8000-A Series User Manual Download Page 203](http://html.mh-extra.com/html/huawei/netcol8000-a-series/netcol8000-a-series_user-manual_166611203.webp)
Step 8 Reassemble the infrared humidifier in an inverse order of
.
Step 9 Power on the unit and tap Maint > Diagnostic Mode > Enter, open the solenoid
valve and the humidifier. Make sure they work properly. Exit the Diagnostic Mode.
Step 10 Tap Maint > Performance Maint to clear the humidifier total runtime.
----End
Replacing the Infrared Humidifier Lamps of the NetCol8000-A100
Recommended tools and materials for replacing a lamp: a Phillips screwdriver, an
adjustable wrench, a 3# hex key, locking pliers, and a new lamp
Step 1 Disconnect the power supply, close the water inlet for the infrared humidifier.
Step 2 Remove the four wiring terminals connecting the manual and automatic reset
switches at the bottom of the water pan using combination pliers, as shown in
.
Step 3 Pull out the self-overflow vent and drain the water from the water pan. After the
water is drained, remove the drainpipe, remove the two screws on the right of the
infrared humidifier.
Figure 7-20 Removing drainpipe and screws on the right side of infrared
humidifier
Step 4 Remove the two butterfly buts on the left, and pull out the water pan horizontally
from the left side.
NetCol8000-A(050, 100) In-room Air Cooled Smart
Cooling Product
User Manual
7 System Operation and Maintenance
Issue 12 (2020-10-28)
Copyright © Huawei Technologies Co., Ltd.
194