EMS Messages
Spooler FASTP Network Print Processes Manual — 427528-006
B - 137
FASTP EMS 512 Text Messages
can only occur when the print process has been improperly started. The most likely
cause is the TACL RUN command was inadvertently used.
Effect.
The FASTP network print process stops.
Recovery.
Do not use TACL RUN commands for FASTP network print processes; use
the normal Spooler mechanism as described in
Configuring a FASTP Network Print
Process
on page 2-4. If the error persists, contact your service provider as described in
Troubleshooting and Reporting Problems
on page 8-1.
512
proc-num
is the process number (CPU, PIN) of the process.
%
nnnnnn
is an octal return code from the PRINTREAD operation. Error codes returned by
the PRINTREAD procedure are described in
the
Spooler Programmer’s Guide
.
Cause.
The FASTP network print process was attempting to extract job data for
printing when an unexpected error was returned by the Spooler PRINTREAD
procedure.
Effect.
The device is placed offline.
Recovery.
If the error persists, contact your service provider as described in
Troubleshooting and Reporting Problems
on page 8-1.
proc-num
Warning - Err: %
nnnnnn
from PRINTREAD