EMS Messages
Spooler FASTP Network Print Processes Manual — 427528-006
B - 125
FASTP EMS 512 Text Messages
svc
is the SVC in use.
job-num
is the job number.
Cause.
This message applies to FASTPX25 only. This error is generated when
FASTPX25 opens an SVC. It is only recorded when bit 2 (%20000) of the PARM
attribute of the Spoolcom DEV command is set.
Effect.
This message is intended to be used a debugging aid.
Recovery.
Informational message only.
512
proc-num
is the process number (CPU, PIN) of the process.
device-name
is the Spooler device name.
param-name
is one of the attributes for FASTPSMB devices.
cnfg-file
is the name of the FASTCNFG file.
Cause.
This message applies to FASTPSMB only. The specified parameter had an
invalid value specified in the FASTCNFG file.
Effect.
No printing occurs, the Spooler job is requeued, and the Spooler device is
placed offline.
Recovery.
Correct the parameter, and restart the Spooler device. (Depending on the
device configuration, the device might restart automatically.)
proc-num
DEV:
device-name
param-name
value in
cnfg-file
is
invalid