RATE CALIBRATION
LO RAT E CAL % 20.0
LOW (L/M) 0.000
HI RAT E CAL % 80.0
Chapter 5 - Calibration
5-17
FIG. 5-9 AUTO RATE CALIBRATION FAILED
3.
If the auto rate calibration passes, the low% reads 30% and high%
reads 60% and can be viewed in the Configuration, Rate Calibra-
tion Screen from the:
•
Front Panel of the controller.
4.
If any one of the points reads zero (0), rate calibration fails. Do the
following:
•
Reset the Time Base (See Chapter 6 for instructions).
Double the Time Base value and repeat the Auto Rate
Calibration process.
•
If any one of the points reads zero (0) again, the rate cali-
bration fails. Contact your local dealer or
Hardy Process
Solutions
, Customer Support for further instructions.
•
To view a percent of deviation from the calibrated norm at
each of the five calibrated percentages. Press the Test but-
ton, scroll to the SELF TEST, press the Enter button and
scroll down until the “OP@” data is viewable.
5.
Set the REC to a working value. (See Setting REC to Zero above
for instructions)
6.
The Automatic Rate Calibration is complete.