I
Load cell input command. Used prima-
rily to check the load cell input section of
the unit. The command will return the
number of averaged counts that is cur-
rently being read from the load cell input.
S (Set) Command
COMMAND
MEANING
S
Set specified SUB-CMD data as follows:
SUB-CMD
MEANING
C HHMM
Set Clock. HHMM represents
hours and minutes.
MD MMDDYY Set Date. MMDDYY represents
month, day and year.
Error Codes
•
The codes are decimal codes returned in response to receiving a
command from the Host.
•
General Communication Return Codes:
Response Code ‘A':
Acknowledge good data received.
Response Code ‘N':
Negative Acknowledge, error code will
follow.
Response #23:
Illegal command while in Hold Mode.
Response #24:
Negative value not allowed.
Response #25:
Invalid interrupt status.
Response #26:
Framing error.
Response #27:
Parity error.
Response #28:
Overrun error.
•
Specific Response Error Codes
C. Time/Date
12
“X TD HHMMSSMMDDYY”
33
50
D. Relay Status
2
“X REL xx”
51
59
E. Remote Functions Stat
2
“X REL xx”
60
58
F. Rate of Change Value
3
“X C xxxxxxx nnn”
69
85
G. Batch Amount
4
“X BA xxxxxxxx”
86
99
H. Set Point Value
3
“X SS xxxxxxxx”
100
113
Description
Bytes
Var
ASCII
Bytes
Format (inside quotes)
From
To
Summary of Contents for HI 2160RC PLUS
Page 1: ...HI 2160RCPLUS Rate Controller Operation and Installation Manual ...
Page 23: ...HI 2160RCPLUS MANUAL 2 6 ...
Page 49: ...HI 2160RCPLUS MANUAL 3 26 ...
Page 67: ...HI 2160RCPLUS MANUAL 4 18 ...
Page 91: ...HI 2160RCPLUS MANUAL 5 24 ...
Page 151: ...HI 2160RCPLUS MANUAL 7 12 ...
Page 187: ...HI 2160RCPLUS MANUAL 8 36 ...
Page 207: ...HI 2160RCPLUS MANUAL 9 20 ...
Page 219: ...Data Worksheets WKSHT 6 ...