HI 2160RC
PLUS
MANUAL
7-6
VALUE
DESCRIPTION
31
address - instrument number 10 - ASCII "1"
30
address - instrument number 10 - ASCII "0"
20
Space
58
X
20
space
47
G
20
space
0D
CR
= 16Dhex
total (365 decimal)
-
100 hex
minus 256 decimal (one byte maximum)
= 6Dhex
total checksum (109 decimal) represented in ASCII
as 36hex (for 6), 44 hex (for D)
2. Serial commands transmitted from the controller to the host in the
form they were received from the host with the return data (and
units) added to the message and a LF added to the CR.
3. Continuing the example, the return data would be:
START
CHAR
INSTRUMENT
ADDRESS
CMD
SUB-CMD
6 BYTE DATA
D6 ... D1
MODE
CR
2 BYTE CHECKSUM
EOT
CHK-1
CHK-2
>
10
X
G
D6 ... d1 LB/KG*
CRLF
CHK-1
CHK-2
EOT
NOTE:
"LB" or "KG" follow data.
a. Data Formats
1)
Weight/Rate Data Format
a) Weights are transmitted according to the following
rules:
•
Positive Numbers:
Maximum of 6 n decimal point.
•
Negative Numbers:**
Maximum of 5 n minus sign + decimal
point.
2)
Examples of transmitted weights: