Chapter 2 - Specifications
2-3
2. Same function as standard serial port but with the capability to
run in multidrop mode and handle long distance (50-1000 ft.)
communications.
3. Interfaces to the 2160 Rate Controller - RS422/485 serial com-
munications with a comprehensive ASCII command set for bi-
directional and multidrop communications over a long range.
ALLEN BRADLEY
Remote I/O Option -
Basic Function
1. Allows the Allen Bradley PLC to fully configure, monitor, and
control the HI2160RC via the AB Remote I/O Interface.
2. Processes both Discrete and Block Transfer commands.
3. Interfaces to the 2160 Rate Controller - Communications on the
Allen Bradley (AB Remote I/O network utilizing a complete
and comprehensive discrete and block transfer command set.
Uses three-wire "Blue Hose" cable to interface with Allen Brad-
ley.
PROFIBUS
Interface Option
Card
1. Allows the Profibus to fully configure, monitor and control the
HI 2160RC PLUS.
2. Interfaces to the HI 2160RC PLUS rate controller. Enables
communications on the Profibus network utilizing comprehen-
sive block and operator selectable output.
Quad Option
Expander Box -
Basic Function (See
Fig. 1-3)
1. Expands the capability of the HI 2160RC PLUS.
2. Houses up to four option cards in its own enclosure.
3. Interfaces to the 2160 Rate Controller - TTL interfacing
between the HI 2160RC PLUS and the quad option box via
quad interface card, installed in the HI 2160RC PLUS option
slot, and a 40 pin ribbon cable.
Analog Output
Option Card
The analog output option outputs Gross, Batch, Rate of Change (ROC),
and total weight as 0-5 V, 0-10V, 0-20 mA or 4-20 mA (or the reverse
of these values via the front panel). The analog output option makes it
possible to span these ranges over a portion of the weight data.
•
Resolution:16,000 counts or limited by the resolution calibrated on
the display.
•
Voltage Out
Maximum Volts: 0-5 or 0-10
Temperature Stability
10 ppm/C or 5 mV total from 30 to 120 F
•
Current Out
Maximum Current:
0-20mA or 4-20mA
Temperature Stability:
20 ppm/C or 20 microampere total from 30 to 120 F
Summary of Contents for HI 2160RC PLUS
Page 1: ...HI 2160RCPLUS Rate Controller Operation and Installation Manual ...
Page 23: ...HI 2160RCPLUS MANUAL 2 6 ...
Page 49: ...HI 2160RCPLUS MANUAL 3 26 ...
Page 67: ...HI 2160RCPLUS MANUAL 4 18 ...
Page 91: ...HI 2160RCPLUS MANUAL 5 24 ...
Page 151: ...HI 2160RCPLUS MANUAL 7 12 ...
Page 187: ...HI 2160RCPLUS MANUAL 8 36 ...
Page 207: ...HI 2160RCPLUS MANUAL 9 20 ...
Page 219: ...Data Worksheets WKSHT 6 ...