5-2
Check for Binding
on Platform Scale/
Feeder
•
Check for binding on the platform scale/feeder and appurtenances
also see your platform scale manual.
•
Check to see that nothing is draped across the platform scale/feeder
such as a hose, electrical cord, tubes, or appurtenances.
•
Check to see that nothing is coming in contact with the platform
scale/feeder other than service wires and piping that have been
properly mounted with flexible connectors.
Direction of
the applied
load
Vessel
FIG. 5-1 PROPERLY INSTALLED LOAD CELL W/NO BINDING
Electrical Check
Procedures
Step 1. Check to see that there is power to the controller.
•
If there is power to the controller The front panel display
should be lit.
Step 2. Allow the controller to warm up for about 15 minutes before
performing the calibration procedures.
Load Check
Step 1. Place a load (weight) on the scale or feeder.
Step 2. Check to see if the weight reading changes on the display in
the proper direction. (e.g. if the display reads 100 pounds and
a 20 pound load is placed on the vessel or scale, the display
should read 120 or some value over 100. If it reads 80 pounds
the reading is going in the wrong direction and indicates some
problem with the system)
Summary of Contents for HI 2160RC PLUS
Page 1: ...HI 2160RCPLUS Rate Controller Operation and Installation Manual ...
Page 23: ...HI 2160RCPLUS MANUAL 2 6 ...
Page 49: ...HI 2160RCPLUS MANUAL 3 26 ...
Page 67: ...HI 2160RCPLUS MANUAL 4 18 ...
Page 91: ...HI 2160RCPLUS MANUAL 5 24 ...
Page 151: ...HI 2160RCPLUS MANUAL 7 12 ...
Page 187: ...HI 2160RCPLUS MANUAL 8 36 ...
Page 207: ...HI 2160RCPLUS MANUAL 9 20 ...
Page 219: ...Data Worksheets WKSHT 6 ...