6.
Use the Selector knob to choose
the program that will execute
after P01 (P02~P12).
OR
Select (Off) to end the Program
Chain after (P01).
OR
Select (P01) to execute after P01,
this will create a continuously
looping Program Chain.
P01
Off – P01~P12
7.
Repeat the above procedure to P02~P12 to
complete the program chain.
The Program Chain ends at the first Program (PXX)
that is followed by Off. It is possible to create
continuously looping program chains.
Save Program
Chain
8.
Press F3 (Save) to save the program
chain.
F1
F5
~
F3
Note
The Program Chain data is not yet saved into Setup
Memory. If you wish to save the Program Chain to
Setup Memory see page 235.
Recall Default
9.
To recall the Default program chain,
press F4.
F1
F5
~
F4
Note
If the Default is recalled, Start will revert to P01 and
all program sequences will be set to Off.
Previous Menu
10.
Press F5 (Previous Menu) to return
the Sequence menu.
F1
F5
~
F5
Summary of Contents for PEL-2000B Series
Page 1: ...Programmable DC Electronic Load PEL 2000B Series USER MANUAL ISO 9001 CERTIFIED MANUFACTURER...
Page 5: ...Table of Contents 5 INDEX 312...
Page 113: ...TUTORIALS 113 14 Sound Turn the sound on off for the mainframe IU Page 202...
Page 309: ...APPENDIX 309 PEL 2004B 435 4 177 532 3 195 3 481 8 554 1 533 3 583 3...
Page 310: ...PEL 2000B Series User Manual 310 PEL 2020B PEL 2030B PEL 2040B PEL 2041B 81 6 171 2 475 446 8...
Page 317: ...INDEX 317 Wiring procedure 46...