GETTING STARTED
29
Power Socket/
Fuse
The power supply socket accepts the
AC mains Voltage. The fuse holder is
located below the power socket.
Power: 47~63Hz
Fuse: T3.15A/250V
For fuse replacement details see page
284.
Channel
Control port
(1~8)
1
CH CONT 1
Each channel has a dedicated Channel
control port to enable external monitoring
and control. The channel control port has 6
wire sockets that are screw-less and self
clamping.
Required wire gauge: 24 AWG
For connection or specification details see
pages 55 & 271.
Remote-IN port
RS232/
RS485
IN
OUT
Two different types of cables can be used
for RS232 or RS485-based remote control.
RS232-232: RS232 cable with DB9
connector kit.
RS485-485: RS485 cable with DB9
connector kit.
Remote-OUT
port
RS232/
RS485
IN
OUT
RJ-45 connector that is used to daisy chain
power supplies with the Remote-IN port to
form a communication bus.