PEL-2000B Series User Manual
184
Configure
Previous
Menu
Protection
Go-NoGo
CH1
Other
Von Voltage
Von Latch
CH CONT
Independent
CC Vrange
V
0.00
OFF
Panel
OFF
High
conf
Group
CCDH
80V
LOAD
USB
Load D-Time
0.0 S
05/04/22
16 : 50
2.
Use the Selector knob to highlight
CH CONT.
3.
Press the Selector knob to edit the
selected setting, turn to change
the setting from Panel to External.
CH CONT
External
4.
Press the Selector knob or Enter
to confirm selection.
ENTER
or
Channel control is now activated.
To turn Channel Control off, CH
CONT must be set to Panel again.
When Channel Control is active,
EXT will be displayed on the side
panel for the active channel.
CH1
conf
CCDH
80V
EXT
Note
Channel Control can only be activated on the active
channel; other channels will not be affected.