PEL-2000B Series User Manual
300
*2
F.S. = Full scale of H Range
PROTECTIVE
Over Power Protection
Range
1~102W
Resolution
0.5W
Accuracy
±(2%set + 0.25% F.S.)
Over Current Protection
Range
0.25~20.4A
Resolution
0.05A
Accuracy
±(2%set + 0.25% F.S.)
Over Voltage Protection
Range
1~81.6V
Resolution
0.2V
Accuracy
±(2%set + 0.25% F.S.)
Over
Temperature
Protection
≒
85°C
Rated Power Protection(CPP)
Value
110W
Accuracy
±5%set
GENERAL
SHORT CIRCUIT
Current(CC)
≒
2.2/2A
≒
22/20A
Voltage(CV)
≒
0V
Resistance(CR)
≒
3.75
Ω
≒
0.075
Ω
Input Resistance
(Load OFF)
500k
Ω
(Typical)
Temperature
Coefficient
100ppm
Weight
Approx. 3.8kg
PEL-2030B (30W/250W)
RANGE
High
Low
High
CURRENT
0~5A
0~4A
0~40A
VOLTAGE
0~80V
MIN.OPERATING
VOLTAGE(dc)
0.8V at 5A
0.4V at 2.5A
0.4V at 4A
0.2V at 2A
0.8V at 40A
0.4V at 20A
STATIC MODE
CONSTANT CURRENT MODE
Operating Range
0~5A
0~4A
0~40A
Setting Range
0~5.1A
0~4.08A
0~40.8A
Summary of Contents for PEL-2000B Series
Page 1: ...Programmable DC Electronic Load PEL 2000B Series USER MANUAL ISO 9001 CERTIFIED MANUFACTURER...
Page 5: ...Table of Contents 5 INDEX 312...
Page 113: ...TUTORIALS 113 14 Sound Turn the sound on off for the mainframe IU Page 202...
Page 309: ...APPENDIX 309 PEL 2004B 435 4 177 532 3 195 3 481 8 554 1 533 3 583 3...
Page 310: ...PEL 2000B Series User Manual 310 PEL 2020B PEL 2030B PEL 2040B PEL 2041B 81 6 171 2 475 446 8...
Page 317: ...INDEX 317 Wiring procedure 46...