PEL-2000B Series User Manual
136
Editing CR Static Parameters
Background
Single channel load modules have two resistance
levels, A Value & B Value. Dual channel load
modules have only one resistance level per
channel, A Value.
When Group Unit Mode is enabled, an additional
parameter, Switch Value, is available to switch
from A Value to B Value.
Ensure the menu is in CR Static Mode. See page
135.
Configure
Configure
Mode
CR
Static
Range
Low
Seq.
Edit
Parameters
A Value
Setting Min ~ Rating Ω
B Value
Setting Min ~ Rating Ω
SlewRate
Load module dependent
SlewRate
Switch Value
A/B (Group Unit Mode only)
Note
When Group Unit Mode is enabled, the A Value & B
Value range is the combined rating of all the units
used in Group Unit Mode.
Panel Operation
1.
Use the Selector knob to highlight
A Value.