![GW Instek PEL-2000B Series User Manual Download Page 303](http://html1.mh-extra.com/html/gw-instek/pel-2000b-series/pel-2000b-series_user-manual_2280092303.webp)
APPENDIX
303
MEASUREMENT
VOLTAGE READBACK
Range
0~16V 0~80V
0~16V
0~80V
Resolution
0.32mV 1.6mV
0.32mV
1.6mV
Accuracy
±(0.025%set + 0.025% F.S.)
CURRENT READBACK
Range
0~5A
0~4A
0~40A
Resolution
0.1mA
0.08mA
0.8mA
Accuracy
±(0.05%set + 0.05% F.S.
*2
)
POWER READBACK
Range
0~30W
0~25W
0~250W
Accuracy
±(0.1%set + 0.1%
F.S.
*1
)
±(0.1%set + 0.1% F.S.
*1
)
NOTE :
*1
Power F.S. = Vrange F.S. x Irange F.S.
*2
F.S. = Full scale of H Range
PROTECTIVE
Over Power Protection
Range
0.9~30.6W
1.25~255W
Resolution
0.15W
1.25W
Accuracy
±(2%set + 0.25%F.S.)
Over Current Protection
Range
0.0625~5.1A
0.5~40.8A
Resolution
0.0125A
0.1A
Accuracy
±(2%set + 0.25%F.S.)
Over Voltage Protection
Range
1~81.6V
Resolution
0.2V
Accuracy
±(2%set + 0.25%F.S.)
Over
Temperature
Protection
≒
85°C
Rated Power Protection(CPP)
Value
33W
275W
Accuracy
±5%set
GENERAL
SHORT CIRCUIT
Current(CC)
≒
5.5/5A
≒
4.4/4A
≒
44/40A
Voltage(CV)
≒
0V
Resistance(CR)
≒
15
Ω
≒
0.3
Ω
≒
1.875
Ω
≒
0.0375
Ω
Input Resistance
(Load OFF)
500k
Ω
(Typical)
Summary of Contents for PEL-2000B Series
Page 1: ...Programmable DC Electronic Load PEL 2000B Series USER MANUAL ISO 9001 CERTIFIED MANUFACTURER...
Page 5: ...Table of Contents 5 INDEX 312...
Page 113: ...TUTORIALS 113 14 Sound Turn the sound on off for the mainframe IU Page 202...
Page 309: ...APPENDIX 309 PEL 2004B 435 4 177 532 3 195 3 481 8 554 1 533 3 583 3...
Page 310: ...PEL 2000B Series User Manual 310 PEL 2020B PEL 2030B PEL 2040B PEL 2041B 81 6 171 2 475 446 8...
Page 317: ...INDEX 317 Wiring procedure 46...