PEL-2000B Series User Manual
138
Select CV Mode
Background
The PEL-2000B series electronic load operates in
four different modes, Constant Current (CC),
Constant Resistance (CR), Constant Voltage (CV),
and Constant Power (CP).
CV Mode cannot be used with the Group Unit
mode.
When a channel is active, the F1 key can
be used to switch between each
operating mode.
F1
F5
~
F1
Mode
CC
Mode
CR
Mode
CV
Mode
CP
Panel Operation
1.
Press the CHAN button and use
the selector knob to select a
channel.
CHAN
LOCAL
2.
Press F1 until CV mode is
displayed in the display panel.
F1
F5
~
F1
Configure
Configure
Mode
CV
Response
Slow1
Range
High
Note
Changing the operating mode will only affect the
current (active) channel. Other channels will not be
affected by any changes.