64
- Chapter 6 - Calibration
G8 Super Cruiser Operator’s Manual MY19 - REV 0
REVISIONS
REV
DESCRIPTION
DATE / INITIAL
ECN
A3
SHEET 1 OF 1
DRAWING NUMBER:
TITLE:
MATERIAL
:
DRAWN BY:
G6 MY19 - Centre section
CENTRE AND PARALIFT REAR ASSEMBLY,
CONFIGURABLE, G6, MY19
J. ROBERTS
NEALHARVEY
MODEL EDITED BY:
21/01/2010
THIS DRAWING REMAINS THE PROPERTY
OF GOLDACRES TRADING PTY LTD AND IS
SUBJECT OF COPYRIGHT
SURFACE FINISH:
WEIGHT:
DRAWING EDITED BY:
4/02/2019
REV
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN MILLIMETRES
SHEET
1-3 MORANG CR. MITCHELL PARK.
VICTORIA 3355 AUSTRALIA
PH: 03 5342 6399
DEBURR AND BREAK
SHARP EDGES
NEALHARVEY
4/02/2019
DRAWING CHECKED BY:
KG
DO NOT SCALE DRAWING
UNLESS OTHERWISE SPECIFIED
0. ± 1 ANGULAR ± 0.50°
0.0 ± 0.5
0.00 ± 0.25
F
F
E
E
D
D
C
C
B
B
A
A
1
1
2
2
3
3
4
4
5
5
6
6
Flow meter
Flow Meter & Pressure Transducer Location
If the sprayed volume from the controller does not
match the tank volume that was sprayed out, then
the flow meter will need to be checked and a new
updated figure input into the ‘Meter Cal’ in the Raven
controller.
• On the flow meter on the sprayer, there will be
a calibration number attached to it on a white
sticker. The number that is applicable is the one
in square brackets, i.e. [185]. Note this number
down as this is the number that should be
entered as the ‘Meter Cal’ number.
• The flow meter should be checked at the start of
every spraying season and periodically during the
season.
• The simplest way to check the accuracy of the
flow meter is to fill the tank to a previously
determined volume mark (usually top fill marking).
while making sure the tank is level.
• On the Raven controller, make sure the ‘Total
Volume’ reads ‘0’.
Flow Meter
The flow control valve regulates the flow going
to the boom sections directed via the console. It
controls the flow to the boom by regulating the
amount of liquid that bypasses back to tank.
The flow control valve is a positive ball valve which
means it can control flow infinitely to the boom
from 0 L/min to the maximum pump output,
dependant on system pressure.
The flow control valve can be operated in manual
mode from the console for boom priming, flushing
and also troubleshooting.
Flow Control Valve
Continued over page
Rate Control Module (RCM)
Consult your Raven RCM operation manual supplied
for detailed setup and calibration information.
Pressure transducer
Summary of Contents for Super Cruiser G8
Page 1: ...Super Cruiser G8 Operator s Manual MY19 GA8700989 REV 0 APR 2019 FROM SERIAL 202114 ...
Page 12: ...8 Chapter 2 Safety G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 18: ...14 Chapter 3 General Information Specs G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 58: ...54 Chapter 4 Cabin G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 74: ...70 Chapter 7 Pre Operation G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 104: ...100 Chapter 8 Operation G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 210: ...www goldacres com au ...