178
- Chapter 12 - Optional Accessories
G8 Super Cruiser Operator’s Manual MY19 - REV 0
PROBLEM
COMMON SOLUTIONS
Meter display will not turn on:
Check for dead battery.
Check electronics chamber for moisture.
Check O-ring seal for damage.
Check to see that PCB assembly is properly seated.
Check to see that battery is properly seated / no corrosion.
Check for damaged magnetic switch/PCB.
Meter shows no flow: (pump runs)
Check low battery indicator.
Check for damaged magnetic switch/PCB.
Check magnetic wheel assembly.
Check nutating chamber for debris.
Check to see if outlet tube is severely restricted (kinked).
Check for missing magnet wheel assembly.
Check to see if out of product.
Flow low/high/inconsistent:
Check for air in system.
Check for calibration error (Err).
Check for particulates in fluid.
Check for damaged nutating chamber.
Meter leaks:
Check for damaged O-ring.
Check for loose screws.
Check inlet/outlet fittings for proper seal.
Check meter housing for cracks.
Noisy / rough operation:
Check nutating chamber for debris.
Check for loose magnetic wheel assembly.
Flow Meter & Pump - Troubleshooting
Summary of Contents for Super Cruiser G8
Page 1: ...Super Cruiser G8 Operator s Manual MY19 GA8700989 REV 0 APR 2019 FROM SERIAL 202114 ...
Page 12: ...8 Chapter 2 Safety G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 18: ...14 Chapter 3 General Information Specs G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 58: ...54 Chapter 4 Cabin G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 74: ...70 Chapter 7 Pre Operation G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 104: ...100 Chapter 8 Operation G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 210: ...www goldacres com au ...