- Chapter 11 - Troubleshooting
G8 Super Cruiser Operator’s Manual MY19 - REV 0
Use the following procedures to the manually
override the boom valves and control valve if the
Raven console has failed or is otherwise not able to
operate them:
RAPIDFIRE AIR VALVE OVERRIDE
1. Disconnect console from console cable.
2. The air valves located on the centre section. Turn
the small screw on the solenoid to turn them on.
3. To start and stop spraying through the nozzles,
start and stop the pump.
For more information on overriding the rapid fire
solenoids, see ‘Rapid Fire’ section in Chapter 8
‘Operation’.
NOTE:
Care should be taken because there is no
agitation while the nozzles are not spraying.
CONTROL VALVE OVERRIDE
• Remove electric motor from three way fast close
valve, and manually rotate valve until desired
spraying pressure is achieved.
• Drive the sprayer at a constant speed in order
to apply the required application volume as
determined by the nozzle selection chart.
The sprayer should then be able to be operated in
order to empty the tank. Once the sprayer is empty
of chemical, partially fill the tank with fresh water
(no chemical) so that testing can be performed in
order to correct the problem. Repair or replace the
console as soon as possible.
Testing Raven Flow Meter Cable
1. Change meter Cal number to 1 with the [Meter
Cal] key.
2.
Press [total volume] key and place boom
switches ON.
3.
With a jumper wire e.g. paper clip, short
between 6 o’clock and 2 o’clock sockets with
a “short” then “no short” motion. Each time
contact is made the [total volume] should move
up in increments of 1 or more.
4. If total volume does not count up, perform test
at the next connector closer to the console.
If this next test works, the previous section of
cable must be faulty and should be replaced.
5.
Perform the voltage checks shown below.
6. Change [Meter Cal] number back to previous
number.
Flow Meter & Controller
Voltage Readings
2 o’clock
-
6 o’clock (+5V DC)
10 o’clock
-
2 o’clock (+5V DC)
Keyway
10 o’clock
Power
6 o’clock
Signal
2 o’clock
Ground
+5V DC
+5V DC
Summary of Contents for Super Cruiser G8
Page 1: ...Super Cruiser G8 Operator s Manual MY19 GA8700989 REV 0 APR 2019 FROM SERIAL 202114 ...
Page 12: ...8 Chapter 2 Safety G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 18: ...14 Chapter 3 General Information Specs G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 58: ...54 Chapter 4 Cabin G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 74: ...70 Chapter 7 Pre Operation G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 104: ...100 Chapter 8 Operation G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 210: ...www goldacres com au ...