146
- Chapter 10 - Lubrication & Maintenance
G8 Super Cruiser Operator’s Manual MY19 - REV 0
Electric Over Hydraulic Controls
The boom and fill pump functions are controlled by
electric over hydraulics solenoids. These solenoids
are energised by functions on the joystick/console in
the cabin and switches on the EZ control station.
The boom functions are controlled by the solenoid
block mounted at the top of the boom centre
section. There is a gauge mounted at the left end of
the block for diagnosis. When a hydraulic function is
used, the hydraulic pressure will increase during that
function.
The boom rest and fill pump are controlled by the
valve block mounted on the cross member of the
chassis under the cabin.
The solenoid valve blocks have various functions.
The directional valve controls oil flow to the desired
circuit. Each particular circuit can be identified by the
tag on the wires attached to the solenoids.
The double operated check valve blocks oil flow
through the solenoid when the solenoid is not
energised. This prevents that function leaking down,
for example if the right hand side of the boom
was tilted up the double operated check valve will
stop oil leaking through when the solenoid is de-
energised and lower the boom, preventing it moving
when the operator is not directing it.
The flow control allows the amount of oil flow to
the hydraulic circuit to be varied thus adjusting the
speed of that circuit. By turning the flow control
adjustment in, clockwise, the flow is reduced thus
reducing the speed at which that hydraulic function
will operate. By turning the flow control out, counter
clockwise, the flow is increased thus increasing the
speed of that hydraulic function.
PORT
DESCRIPTION
P
Pressure supply
T
Return to reservoir
A & B
Bi-fold and tilt cylinder connections
L1 & L2
Lift cylinders & yaw charge circuit
Hydraulics - 36-42m
Continued over page
Boom Lower/Raise
Pressure
Gauge
Left Tilt
Right Tilt
Bi-fold
Centre Lock
F
E
D
E
F
C
1
2
3
4
B
A
3
2
1
5
C
D
4
6
7
8
A
B
A3
SHEET 3 OF 3
SCALE:1:2.5
DWG NO.
TITLE:
GOLDACRES
DO NOT SCALE DRAWING
Material
:
Drawn By:
1-3 MORANG CR
MITCHELL PARK 3352
PH: 03 53426399
FAX: 03 53426308
GA4907650
Manifold Assembly with Fittings, Normally Closed
Spool Valve with AMP Connectors, G8, MY16
NealHarvey
REV NO
CHANGE
NAME/DATE ECN NO.
DATE EDITED:
4/06/2012
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE
IN MILLIMETRES
UNTOL. DIMENSIONS
OPEN DIM ± 1.00
ANGULAR ± 0.50°
UNLESS OTHERWISE
TOLERANCED
THIS DRAWING REMAINS THE PROPERTY
OF GOLDACRES TRADING PTY LTD AND IS
SUBJECT OF COPYRIGHT
Surface Finish:
Approved
FINISHED WEIGHT:
Kg
Drawing Checked:
30/05/2017
REV
DRG. STANDARD
/PRACTICE
AS 1100
DEBUR ALL EDGES
Boom Fold
Below:
Spool valve block.
Unloader
Summary of Contents for Super Cruiser G8
Page 1: ...Super Cruiser G8 Operator s Manual MY19 GA8700989 REV 0 APR 2019 FROM SERIAL 202114 ...
Page 12: ...8 Chapter 2 Safety G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 18: ...14 Chapter 3 General Information Specs G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 58: ...54 Chapter 4 Cabin G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 74: ...70 Chapter 7 Pre Operation G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 104: ...100 Chapter 8 Operation G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 210: ...www goldacres com au ...