Chapter 4 - Cabin -
27
G8 Super Cruiser Operator’s Manual MY19 - REV 0
Lighting
Egress Lighting
These machines are fitted with egress lighting to
assist with safely exiting the machine when parking in
dark conditions. There is a timed relay that will keep
the outside work lights on for 30 seconds after the
machine has been shut down and the key removed.
The amount of time that the relay keeps the lights
on for can be adjusted. It is found inside the main
cabin fuse box area.
Above:
Egress lighting timer relay location in main
fuse box area.
Above:
Timer relay potentiometer and dip switches.
By default, the timer potentiometer is set to 30
seconds (A). It has a range between 0 and 60
seconds. Turning it clockwise increases the timer.
Turning it anti-clockwise decreases the timer.
The two dimples in the white adjuster indicate the
direction it is pointing in.
The two dip switches are set to the OFF position by
default (B). If a lighting time longer than 60 seconds
(1 minute) is required, then dip switch 2 can be set
to the ON position. On this setting, each increment
on the potentiometer represents 1 minute, for a
maximum of range of 1 to 60 minutes.
B
A
Summary of Contents for Super Cruiser G8
Page 1: ...Super Cruiser G8 Operator s Manual MY19 GA8700989 REV 0 APR 2019 FROM SERIAL 202114 ...
Page 12: ...8 Chapter 2 Safety G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 18: ...14 Chapter 3 General Information Specs G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 58: ...54 Chapter 4 Cabin G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 74: ...70 Chapter 7 Pre Operation G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 104: ...100 Chapter 8 Operation G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 210: ...www goldacres com au ...