148
- Chapter 10 - Lubrication & Maintenance
G8 Super Cruiser Operator’s Manual MY19 - REV 0
Centre Levelling System
The centre levelling system requires adjustment
when the boom is folding closed unevenly. See the
tilt adjustment procedure in Chapter 8.
Hydraulic Yaw
The hydraulic yaw circuit typically only requires
attention when changing a component such as a
hose or ram that would allow air into the system.
See the air bleeding procedure in Chapter 8.
Another situation that would require attention is
when the yaw suspension seems to firm or too soft
and is not controlling the boom movement well. In
that case the system pressure should be adjusted.
See pressure adjustment procedure in Chapter 8.
Above:
Hydraulic yaw circuit pressure gauges &
valves.
Hydraulics - 36-42m
Above:
Double pilot operated check valves are
mounted to the bi-fold cylinders.
Above:
Centre level & cable adjusters.
Summary of Contents for Super Cruiser G8
Page 1: ...Super Cruiser G8 Operator s Manual MY19 GA8700989 REV 0 APR 2019 FROM SERIAL 202114 ...
Page 12: ...8 Chapter 2 Safety G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 18: ...14 Chapter 3 General Information Specs G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 58: ...54 Chapter 4 Cabin G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 74: ...70 Chapter 7 Pre Operation G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 104: ...100 Chapter 8 Operation G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Page 210: ...www goldacres com au ...