ENUMERATION: FRONT PANEL INTERFACE KEYPRESS
F531
ENUMERATION: LANGUAGE
0 = English, 1 = French, 2 = Chinese, 3 = Russian
F540
ENUMERATION: PMU POST-FILTER
0 = None, 1 = Symm-3-Point, 2 = Symm-5-Point,
3 = Symm-7-Point, 4 = Class M, 5 = Class P
F542
ENUMERATION: PMU TRIGGERING MODE
0 = Automatic Overwrite, 1 = Protected
F543
ENUMERATION: PMU PHASORS
F544
ENUMERATION: PMU RECORDING/REPORTING RATE
F545
ENUMERATION: PMU COM PORT TYPE
0 = Network, 1 = RS485, 2 = Dir Comm Ch1, 3 = Dir Comm Ch2,
4 = GOOSE, 5 = None
F546
ENUMERATION: PMU REPORTING STYLE
0 = Polar, 1 = Rectangular
F547
ENUMERATION: PMU REPORTING FORMAT
0 = Integer, 1 = Floating
F550
ENUMERATION: RTD INPUT APPLICATION
F552
ENUMERATION: RTD INPUT OPEN
F600
UR_UINT16: FLEXANALOG PARAMETER
Corresponds to the Modbus address of the value used when this
parameter is selected. Only certain values can be used as FlexAn-
alogs (basically all metering quantities used in protection).
Value
Keypress
Value
Keypress
Value
Keypress
0
None
15
3
33
User PB 3
1
Menu
16
Enter
34
User PB 4
2
Message Up
17
Message
Down
35
User PB 5
3
7
~
18
0
~
36
User PB 6
4
8
19
Decimal
37
User PB 7
5
9
20
+/–
38
User PB 8
6
Help
21
Value Up
39
User PB 9
7
Message Left
22
Value Down
40
User PB 10
8
4
23
Reset
41
User PB 11
9
5
24
User 1
42
User PB 12
10
6
25
User 2
44
User 4
11
Escape
26
User 3
45
User 5
12
Message
Right
31
User PB 1
46
User 6
13
1
32
User PB 2
47
User 7
14
2
Value
Phasor
Value
Phasor
0
Off
8
Ig
1
Va
9
V1
2
Vb
10
V2
3
Vc
11
V0
4
Vx
12
I1
5
Ia
13
I2
6
Ib
14
I0
7
Ic
Value
Rate
Value
Rate
0
1/second
6
15/second
1
2/second
7
20/second
2
4/second
8
25/second
3
5/second
9
30/second
4
10/second
10
50/second
5
12/second
11
60/second
Enumeration
RTD input application
0
None
1
Stator
2
Bearing
3
Ambient
4
Group 1
5
Group 2
Enumeration
RTD open
0
None
1
Alarm
2
Block
Summary of Contents for UR T60
Page 10: ...x T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Page 14: ...xiv T60 Transformer Protection System GE Multilin 0 1 BATTERY DISPOSAL 0 BATTERY DISPOSAL 0 ...
Page 34: ...1 20 T60 Transformer Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 436: ...5 298 T60 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 678: ...C 30 T60 Transformer Protection System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Page 688: ...D 10 T60 Transformer Protection System GE Multilin D 1 IEC 60870 5 104 PROTOCOL APPENDIX D D ...
Page 700: ...E 12 T60 Transformer Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...