B-26
T60 Transformer Protection System
GE Multilin
B.4 MEMORY MAPPING
APPENDIX B
B
40B6
DNP Voltage Default Deadband
0 to 100000000
---
1
F003
30000
40B8
DNP Power Default Deadband
0 to 100000000
---
1
F003
30000
40BA
DNP Energy Default Deadband
0 to 100000000
---
1
F003
30000
40BC
DNP Power Factor Default Deadband
0 to 100000000
---
1
F003
30000
40BE
DNP Other Default Deadband
0 to 100000000
---
1
F003
30000
40C0
DNP IIN Time Synchronization Bit Period
1 to 10080
min
1
F001
1440
40C1
DNP Message Fragment Size
30 to 2048
---
1
F003
240
40C2
DNP Client Address 3
0 to 4294967295
---
1
F003
0
40C4
DNP Client Address 4
0 to 4294967295
---
1
F003
0
40C6
DNP Client Address 5
0 to 4294967295
---
1
F003
0
40C8
DNP Number of Paired Binary Output Control Points
0 to 32
---
1
F001
0
40C9
DNP TCP Connection Timeout
10 to 7200
s
1
F001
120
40CA
DNP Communications Reserved (22 items)
0 to 1
---
1
F001
0
40E0
TCP Port Number for the IEC 60870-5-104 Protocol
1 to 65535
---
1
F001
2404
40E1
IEC 60870-5-104 Protocol Function
0 to 1
---
1
F102
0 (Disabled)
40E2
IEC 60870-5-104 Protocol Common Address of ASDU
0 to 65535
---
1
F001
0
40E3
IEC 60870-5-104 Protocol Cyclic Data Transmit Period
1 to 65535
s
1
F001
60
40E4
IEC 60870-5-104 Current Default Threshold
0 to 100000000
---
1
F003
30000
40E6
IEC 60870-5-104 Voltage Default Threshold
0 to 100000000
---
1
F003
30000
40E8
IEC 60870-5-104 Power Default Threshold
0 to 100000000
---
1
F003
30000
40EA
IEC 60870-5-104 Energy Default Threshold
0 to 100000000
---
1
F003
30000
40EC
IEC 60870-5-104 Power Default Threshold
0 to 100000000
---
1
F003
30000
40EE
IEC 60870-5-104 Other Default Threshold
0 to 100000000
---
1
F003
30000
40F0
IEC 60870-5-104 Client Address (5 items)
0 to 4294967295
---
1
F003
0
4104
IEC 60870-5-104 Redundancy Port Enabled/Disabled
0 to 1
---
1
F126
0 (No)
4105
IEC Communications Reserved (57 items)
0 to 1
---
1
F001
0
413E
High Enet Traffic Function
0 to 1
---
1
F102
0 (Disabled)
413F
High Enet Traffic Events
0 to 1
---
1
F102
0 (Disabled)
4140
DNP Object 1 Default Variation
1 to 2
---
1
F001
2
4141
DNP Object 2 Default Variation
1 to 3
---
1
F001
2
4142
DNP Object 20 Default Variation
0 to 3
---
1
F523
0 (1)
4143
DNP Object 21 Default Variation
0 to 3
---
1
F524
0 (1)
4144
DNP Object 22 Default Variation
0 to 3
---
1
F523
0 (1)
4145
DNP Object 23 Default Variation
0 to 3
---
1
F523
0 (1)
4146
DNP Object 30 Default Variation
1 to 5
---
1
F001
1
4147
DNP Object 32 Default Variation
0 to 5
---
1
F525
0 (1)
Ethernet Switch (Read/Write Setting)
4148
Ethernet Switch IP Address
0 to 4294967295
---
1
F003
3232235778
414A
Ethernet Switch Modbus IP Port Number
1 to 65535
---
1
F001
502
414B
Ethernet Switch Port 1 Events
0 to 1
---
1
F102
0 (Disabled)
414C
Ethernet Switch Port 2 Events
0 to 1
---
1
F102
0 (Disabled)
414D
Ethernet Switch Port 3 Events
0 to 1
---
1
F102
0 (Disabled)
414E
Ethernet Switch Port 4 Events
0 to 1
---
1
F102
0 (Disabled)
414F
Ethernet Switch Port 5 Events
0 to 1
---
1
F102
0 (Disabled)
4150
Ethernet Switch Port 6 Events
0 to 1
---
1
F102
0 (Disabled)
Ethernet Switch (Read Only Actual Values)
4151
Ethernet Switch MAC Address
---
---
---
F072
0
4154
Ethernet Switch Port 1 Status
0 to 2
---
1
F134
0 (Fail)
4155
Ethernet Switch Port 2 Status
0 to 2
---
1
F134
0 (Fail)
4156
Ethernet Switch Port 3 Status
0 to 2
---
1
F134
0 (Fail)
4157
Ethernet Switch Port 4 Status
0 to 2
---
1
F134
0 (Fail)
4158
Ethernet Switch Port 5 Status
0 to 2
---
1
F134
0 (Fail)
4159
Ethernet Switch Port 6 Status
0 to 2
---
1
F134
0 (Fail)
415A
Switch Firmware Version
0.00 to 99.99
---
0.01
F001
0
Table B–10: MODBUS MEMORY MAP (Sheet 18 of 65)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for UR T60
Page 10: ...x T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Page 14: ...xiv T60 Transformer Protection System GE Multilin 0 1 BATTERY DISPOSAL 0 BATTERY DISPOSAL 0 ...
Page 34: ...1 20 T60 Transformer Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 436: ...5 298 T60 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 678: ...C 30 T60 Transformer Protection System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Page 688: ...D 10 T60 Transformer Protection System GE Multilin D 1 IEC 60870 5 104 PROTOCOL APPENDIX D D ...
Page 700: ...E 12 T60 Transformer Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...