12.3.5 NEC and UL Compliance
Fuses or Circuit Breakers must comply with NEC 2009. We
recommend using a selection of the following.
The fuses below are suitable for use on a circuit capable of
delivering 100,000 Arms (symmetrical), 240 V, or 480 V, or
600 V depending on the drive voltage rating. With the
proper fusing, the drive Short Circuit Current Rating (SCCR)
is 100,000 Arms.
Recommended max. fuse
AF-600 1-
phase
Power
AF-600 3-
phase
Power
Bussmann
Bussmann
Bussmann
Bussmann
Bussmann
Bussmann
[kW]/[HP] [kW]/[HP]
Type RK1
1)
Type J
Type T
Type CC
Type CC
Type CC
0.75/1
KTN-R-10
JKS-10
JJN-10
FNQ-R-10
KTK-R-10
LP-CC-10
1.5/2
KTN-R-15
JKS-15
JJN-15
FNQ-R-15
KTK-R-15
LP-CC-15
1.5/2
2.2/3
KTN-R-20
JKS-20
JJN-20
FNQ-R-20
KTK-R-20
LP-CC-20
2.2/3
3.7/5
KTN-R-30
JKS-30
JJN-30
FNQ-R-30
KTK-R-30
LP-CC-30
3.7/5
5.5–
7.5/7.5–
10
KTN-R-50
KS-50
JJN-50
-
-
-
5.5/7.5
11/15
KTN-R-60
JKS-60
JJN-60
-
-
-
7.5/10
15/20
KTN-R-80
JKS-80
JJN-80
-
-
-
18.5–
22/25–30
KTN-R-125
JKS-125
JJN-125
-
-
-
15/20
30/40
KTN-R-150
JKS-150
JJN-150
-
-
-
23/30
37/50
KTN-R-200
JKS-200
JJN-200
-
-
-
45/60
KTN-R-250
JKS-250
JJN-250
-
-
-
Table 12.12 200–240 V
Recommended max. fuse
AF-600 1-
phase
Power
AF-600 3-
phase
Power
SIBA
Littel fuse
Ferraz-
Shawmut
Ferraz-
Shawmut
[kW]/[HP] [kW]/[HP]
Type RK1
Type RK1
Type CC
Type RK1
3)
0.75/1
5017906-010
KLN-R-10
ATM-R-10
A2K-10-R
1.5/2
5017906-016
KLN-R-15
ATM-R-15
A2K-15-R
1.5/2
2.2/3
5017906-020
KLN-R-20
ATM-R-20
A2K-20-R
2.2/3
3.7/5
5012406-032
KLN-R-30
ATM-R-30
A2K-30-R
3.7/5
5.5–
7.5/7.5–
10
5014006-050
KLN-R-50
-
A2K-50-R
5.5/7.5
11/15
5014006-063
KLN-R-60
-
A2K-60-R
7.5/10
15/20
5014006-080
KLN-R-80
-
A2K-80-R
18.5–
22/25–30
2028220-125
KLN-R-125
-
A2K-125-R
15/20
30/40
2028220-150
KLN-R-150
-
A2K-150-R
23/30
37/50
2028220-200
KLN-R-200
-
A2K-200-R
45/60
2028220-250
KLN-R-250
-
A2K-250-R
Table 12.13 200–240 V
Specifications
AF-600 FP Design and Installation Guide
12-20
DET-768A
12
2
Summary of Contents for AF-600 FP Series
Page 1: ...AF 600 FPTM Fan Pump Drive Design and Installation Guide GE ...
Page 17: ...Introduction AF 600 FP Design and Installation Guide 1 10 DET 768A 1 1 ...
Page 39: ...Start Up and Functional Tes AF 600 FP Design and Installation Guide 3 6 DET 768A 3 3 ...
Page 57: ...About Programming AF 600 FP Design and Installation Guide 5 14 DET 768A 5 5 ...
Page 73: ...Application Set up Examples AF 600 FP Design and Installation Guide 6 16 DET 768A 6 6 ...
Page 83: ...Installation Consideration AF 600 FP Design and Installation Guide 7 10 DET 768A 7 7 ...
Page 87: ...Status Messages AF 600 FP Design and Installation Guide 8 4 DET 768A 8 8 ...
Page 97: ...Warnings and Alarms AF 600 FP Design and Installation Guide 9 10 DET 768A 9 9 ...
Page 101: ...Basic Troubleshooting AF 600 FP Design and Installation Guide 10 4 DET 768A 10 0 ...
Page 103: ...Terminal and Applicable Wir AF 600 FP Design and Installation Guide 11 2 DET 768A 11 1 ...