Feeding
123
value increases continuously and at the end of the feeding
period it achieves 90 %. If necessary, the maximum speed plan
can be subdivided into up to 5 periods. The value relating to the
maximum speed can be 30 to 100 %.
1.
>
feeding
>
plans
>
feed > max. speed
2. Select the desired group. The related default plan of the max-
imum speed is displayed.
3. In
P 1
enter the duration (number of days) of the first feeding
period.
4. Press
to move to the column
from
and enter the initial
value for the maximum speed.
5. Press
to move to
to
and enter the final value for the max-
imum speed.
6. To change the values for
P 2
to
P 5
, proceed as with
P 1
.
7. The last menu line shows the total duration of the maximum
speed plan.
8.4
Alarm levels
The alarm levels allow you to determine the time or the value as
of which an alarm is given. The alarm levels are determined per
group.
You can enter alarm levels for:
•
Feed consumption
•
Feeding speed
Default values of the maximum speed plan for the groups
A, B, C and D
P(eriod) 1: Start value: 70 %, End value: 90 %
P(eriods) 2 to 5 are not activated as a standard.
<group A>
days from to %
P 1: [70 50 80]
P 2: 0 0 0
duration: 70 days
alarm levels
feed
Summary of Contents for TAK5-CH1-25
Page 38: ...38 Operation ...
Page 54: ...54 Start up ...
Page 70: ...70 Setup ...
Page 84: ...84 Device data ...
Page 90: ...90 Calibration ...
Page 150: ...150 Cleaning ...
Page 170: ...170 Animal control ...
Page 192: ...192 Failures and warnings ...
Page 196: ...196 Care and maintenance plan Routine tasks ...
Page 215: ......
Page 218: ...218 Annex 16 3 5 Template for individual feeding plan ...
Page 219: ...Annex 219 16 4 Basic principle of interval feeding ...
Page 222: ...222 Annex ...