![Foerster TAK5-CH1-25 Instruction Manual Download Page 60](http://html1.mh-extra.com/html/foerster/tak5-ch1-25/tak5-ch1-25_instruction-manual_2314657060.webp)
60
Setup
Circulation valve
Here you can select:
•
HE (= heat exchanger): This valve is part of the standard
equipment of all Profi models. For all Farmer models it is an
option. It facilitates all-automatic heat exchanger cleaning.
•
Valve: The
cleaning valve
is part of the standard equip-
ment of all Farmer models. It facilitates all-automatic cold wa-
ter cleaning of the box valves.
Air valve
The air valve is part of the compressed-air cleaning system.
Mixer sensor
The sensor in the mixer continuously records the temperature of
the feed in the mixer jar. If the temperature does not comply with
the target value, the boiler heating will be readjusted. This
means that the animals are always fed with the desired temper-
ature - irrespective of the season.
Circulation pump
The circulation pump ensures that the heat of the boiler water is
rapidly and uniformly transferred to the liquid in the stainless
steel coil.
Water meter
The factory-set value (
yes
) must remain unchanged.
Supply and spot electrode
The setting referring to the supply and the spot electrode must
be
yes
.
The setting referring to the supply and the spot electrode must
be
no
.
equipment
...
air valve: [ no]
circ. pump: yes
mixer sensor: yes
water meter: yes
supply el.: yes
spot el.: yes
MilkMaker: no
Summary of Contents for TAK5-CH1-25
Page 38: ...38 Operation ...
Page 54: ...54 Start up ...
Page 70: ...70 Setup ...
Page 84: ...84 Device data ...
Page 90: ...90 Calibration ...
Page 150: ...150 Cleaning ...
Page 170: ...170 Animal control ...
Page 192: ...192 Failures and warnings ...
Page 196: ...196 Care and maintenance plan Routine tasks ...
Page 215: ......
Page 218: ...218 Annex 16 3 5 Template for individual feeding plan ...
Page 219: ...Annex 219 16 4 Basic principle of interval feeding ...
Page 222: ...222 Annex ...