Cleaning
139
9
Cleaning
The automatic feeder has to be cleaned at regular intervals, par-
ticularly when fresh milk is fed. The following cleaning menus
can be selected:
•
Mixer
•
Heat exchanger
(serial equipment with
)
•
Circuit cleaning
•
Air
(pulsating compressed-air cleaning)
•
(
Box) valves
•
Sponge
(= heat exchanger cleaning with sponge)
•
Hose
•
Settings
9.1
Settings
In this menu you can enter:
•
the temperature of the cleaning water,
•
the detergent quantity,
•
whether the teat should be cleaned.
1.
>
cleaning
>
settings
cleaning
mixer
heat exchanger
circuit cleaning
air
valves
sponge
hose rinsing
settings
Note:
certain failures prevent the start of cleaning pro-
cesses, e.g. when water or detergent have not been cal-
ibrated yet.
Type and frequency of the cleaning process depend on
the composition and the germ-content of the milk to be
fed.
Warning
: Detergent can be harmful to health. Therefore
make sure that only authorized persons have access to
it.
settings
temperature: [45]°C
detergent: 0 ml/L
clean teat: no
Summary of Contents for TAK5-CH1-25
Page 38: ...38 Operation ...
Page 54: ...54 Start up ...
Page 70: ...70 Setup ...
Page 84: ...84 Device data ...
Page 90: ...90 Calibration ...
Page 150: ...150 Cleaning ...
Page 170: ...170 Animal control ...
Page 192: ...192 Failures and warnings ...
Page 196: ...196 Care and maintenance plan Routine tasks ...
Page 215: ......
Page 218: ...218 Annex 16 3 5 Template for individual feeding plan ...
Page 219: ...Annex 219 16 4 Basic principle of interval feeding ...
Page 222: ...222 Annex ...