Failures and warnings
181
12.1.16
IFS-version
In the parallel mode (SynchroFeed) at least one of the feeding
stations supplied with feed at the same time is operated by a
peristaltic pump together with the relevant IFS-control unit.
The software version of the IFS-control units used for parallel
operation must be 5.00 (or greater).
12.1.17 Output error
The control of specific relays is permanently monitored by an
electronic protective device. If these relays are actuated for more
than 60 seconds, a fault may be the reason for it. The fault mes-
sage
output error
will be displayed and feeding is automatically
broken off.
1. Switch the automatic feeder off and after some seconds on
again.
2. If the message reappears, you should contact service person-
nel.
This message is also displayed when a short circuit occurs on a
cable connecting the automatic feeder to an external component
(e.g. the antenna or the hand-held terminal).
Exclusively for service personnel:
1. Check the cable connections.
2. Replace the cable(s).
failure
incorrect version
<IFS-F 1 >
version 5.00 or
greater required
Note
: This failure cannot be deleted. The IFS-control(s)
must be updated to be operated in the parallel mode.
failure
output error
Summary of Contents for TAK5-CH1-25
Page 38: ...38 Operation ...
Page 54: ...54 Start up ...
Page 70: ...70 Setup ...
Page 84: ...84 Device data ...
Page 90: ...90 Calibration ...
Page 150: ...150 Cleaning ...
Page 170: ...170 Animal control ...
Page 192: ...192 Failures and warnings ...
Page 196: ...196 Care and maintenance plan Routine tasks ...
Page 215: ......
Page 218: ...218 Annex 16 3 5 Template for individual feeding plan ...
Page 219: ...Annex 219 16 4 Basic principle of interval feeding ...
Page 222: ...222 Annex ...