![Foerster TAK5-CH1-25 Instruction Manual Download Page 148](http://html1.mh-extra.com/html/foerster/tak5-ch1-25/tak5-ch1-25_instruction-manual_2314657148.webp)
148
Cleaning
The sponge is pressed by the water through the stainless steel
coil.
7. As soon as
sponge cleaning
is completed, remove the
sponge ball from the mixer jar.
8. Confirm
sponge removed?
with
.
9. The cleaning water is drained off via the mixer draining valve,
if available. If the draining valve is missing, tip over the mixer
jar to empty it.
10.Rinse with clear water. To do so, use the menu „water HE“ in
the manual functions (
).
9.8
Rinsing the hose
The suction hose can be rinsed each time a calf visits the feed-
ing station.
As soon as an animal has drunk up the last portion to which it is
entitled, the automatic feeder dispenses 0.25 liters of warm
water into the mixer jar (after draining time has lapsed). As an
animal usually stays a little bit longer in the feeding station suck-
ling at the teat, in this way the suction hose can be easily rinsed.
1.
>
cleaning
>
hose rinsing
2. Select the desired group.
sponge
inserted?
sponge
removed?
Note:
If there is some air in the hose, the water will not
drain off. You can activate the feeding pump in support
of this process. To do so, press
.
Note:
If the cleaning sponge pushes forward dirt or de-
posits, you should repeat the cleaning process immedi-
ately afterwards and later on at regular intervals.
cleaning
...
hose
...
Summary of Contents for TAK5-CH1-25
Page 38: ...38 Operation ...
Page 54: ...54 Start up ...
Page 70: ...70 Setup ...
Page 84: ...84 Device data ...
Page 90: ...90 Calibration ...
Page 150: ...150 Cleaning ...
Page 170: ...170 Animal control ...
Page 192: ...192 Failures and warnings ...
Page 196: ...196 Care and maintenance plan Routine tasks ...
Page 215: ......
Page 218: ...218 Annex 16 3 5 Template for individual feeding plan ...
Page 219: ...Annex 219 16 4 Basic principle of interval feeding ...
Page 222: ...222 Annex ...