190
Failures and warnings
> Check the CAN-bus for short-circuit resp. other failures and
remove it/them.
12.3.1.2 CAN bus heavy
The reasons for the message on the right may be the following:
•
Short-circuit
> Check the CAN-bus for short-circuit.
•
The terminator has not been mounted.
> Check whether the terminators have been mounted correctly.
•
The data line is interrupted.
•
The CAN-cable is clamped incorrectly.
•
There is no connection to the control of the automatic feeder.
> Check whether the data line is wired correctly and the control
of the automatic feeder is working properly.
12.3.1.3 Waiting
The reason for the message on the right is: The hand-held termi-
nal is not initialized because
•
the CAN-bus address of the terminal does not correspond to
the one configured in the setup of the automatic feeder.
•
the control of the automatic feeder is not active.
1. Start the search mode: Press
when switching the au-
tomatic feeder on and keep the keys pressed.
2. If the message reappears, you must check whether the con-
trol of the automatic feeder is working properly.
12.3.1.4 Searching
The reaon for the message on the right is the following: The
hand-held terminal is in the search-mode.
terminal Vxx.xx
CAN bus heavy
terminal Vxx.xx
waiting
terminal Vxx.xx
searching
Summary of Contents for TAK5-CH1-25
Page 38: ...38 Operation ...
Page 54: ...54 Start up ...
Page 70: ...70 Setup ...
Page 84: ...84 Device data ...
Page 90: ...90 Calibration ...
Page 150: ...150 Cleaning ...
Page 170: ...170 Animal control ...
Page 192: ...192 Failures and warnings ...
Page 196: ...196 Care and maintenance plan Routine tasks ...
Page 215: ......
Page 218: ...218 Annex 16 3 5 Template for individual feeding plan ...
Page 219: ...Annex 219 16 4 Basic principle of interval feeding ...
Page 222: ...222 Annex ...